Handheld thyroid ultrasound machines for the endocrine clinic
Eight real neck and metabolic captures from Suresult wireless hardware, including a cystic and solid thyroid nodule at 55 mm. Seven models compared by frequency and needle guidance, with the L14 at $2,139, software included and no subscription.
Respuesta rápida
A thyroid ultrasound machine is a high-frequency linear scanner that images the thyroid gland and the neck, so a clinician can size a nodule during the visit.
- The AIUM head and neck practice parameter prefers mean frequencies of 10 to 14 MHz or greater. The Suresult L14 and L14Pro reach 14 MHz.
- Color, power and pulsed-wave Doppler with M-mode run on every model on this page, with no membership.
- In-plane and out-of-plane puncture guides sit in the app, and the L10H additionally lists visualized needle guidance for aspiration work.
- The D3Ultra carries a 7.5/10 MHz linear head for the gland and a convex head reaching 300 mm. The liver of a metabolic patient fits in the same visit.
The capture atlas
Eight real neck and metabolic windows from the Suresult clinical reference library
Unedited clinical captures · select any image to enlarge
Gland survey3 windows
Transverse neck: the gland beside the vessel
A round anechoic vessel sits on the left of the frame and the gland fills the middle as an even mid-gray band. This is the orientation view that every thyroid scan starts from.
40 mm depth, harmonic 10 MHz, gain 69 dB, dynamic range 60, enhancement 3, frame 33 of 33, 25 February 2020. Header identity fields are demo entries. The file records the wireless 128-element linear head.Long axis through the lobe
The lobe runs across the frame under the strap muscle layer, with an even speckle and no focal lesion in this plane. Gain is held at 59 dB so the parenchyma keeps its texture.
40 mm depth, harmonic 10 MHz, gain 59 dB, dynamic range 70, enhancement 4, frame 100 of 100, 26 February 2020, wireless linear headParenchyma with small vessels crossing it
Two small vessel cross-sections and one longitudinal vessel run through the gland, which is how the normal texture reads at 10 MHz. The mechanical index shows 0.9 and the thermal index 0.2.
40 mm depth, harmonic 10 MHz, gain 69 dB, dynamic range 60, MI 0.9, TIS 0.2, frame 16 of 16, 25 February 2020, wireless 128-element linear headNodule1 window
Cystic and solid nodule at 55 mm
Two anechoic spaces sit inside the gland with a bright septation between them and solid tissue around them. The file is recorded in the library as a cystic and solid thyroid nodule.
55 mm depth, harmonic 10 MHz, gain 81 dB, dynamic range 60, enhancement 4, frame 45 of 45, 6 February 2018, wireless linear headCervical nodes2 windows
Cervical node with an echogenic hilum
A hypoechoic oval node carries a bright hilum through its center and a thin even cortex around it. The hilum is the structure a nodal survey looks for first.
55 mm depth, harmonic 10 MHz, gain 65 dB, dynamic range 70, enhancement 1, frame 13 of 13, 22 February 2018, wireless linear headFlat node measured on the app
Two calipers sit on a flat node and the app returns 26.51 mm along the long axis and 5.97 mm across the short axis. Measurement runs on the scanner without any extra software.
40 mm depth, harmonic 10 MHz, gain 77 dB, dynamic range 70, frame 54 of 54, 16 March 2019. On-screen lengths read 26.51 mm and 5.97 mm on the wireless linear head.Vessels and the metabolic screen2 windows
Neck vessels in color on the D3Ultra
The color box covers two vessels in cross-section, one filling red and the other blue as flow runs in opposite directions. The scale reads plus or minus 11.6 cm/s at a pulse repetition frequency of 2.0 kHz.
captured on a D3Ultra, 19 May 2023. 40 mm depth, harmonic 10 MHz, gain 72 dB, color gain 39, steer 7 degrees, PRF 2.0 kHz, wall filter 7, frame 180 of 201Fatty liver on the convex head at 200 mm
The liver returns a bright fine echo pattern against the vessel walls running through it, captured at 3.5 MHz with the depth opened to 200 mm. The file is recorded in the library as fatty liver.
200 mm depth, 3.5 MHz, gain 74 dB, dynamic range 80, enhancement 2, frame 96 of 100, 15 March 2018, wireless convex headSelect a card to switch capture
Technique basics
How the exam comes together, probe to report
Take the linear head and open at 40 mm.
The gland sits inside the first 40 mm of the neck in most adults. The linear head at 40 mm holds the whole lobe and the tissue behind it. Harmonic imaging at 10 MHz is the starting setting on these captures.
D: 40 mm, F: H10.0 MHz on the headerFix the landmarks before reading anything.
The common carotid artery and the internal jugular vein run side by side in long axis in this frame, which is the landmark pair for the lateral neck. Holding that pair in view keeps the probe oriented while it slides from isthmus to upper pole.
7.5 MHz, 40 mm, dynamic range 70Drop the color box on the finding.
Color Doppler answers the vascularity question, and the pulse repetition frequency decides what flow appears. This frame runs at 2.0 kHz with the box steered 7 degrees and color gain at 39.
PRF 2.0 kHz, steer 7 degrees, color gain 39Change heads for the metabolic question.
A patient with type 2 diabetes often needs the liver looked at as well, and the D3Ultra convex head opens to 300 mm on the same device. This frame runs color at 5 MHz with depth at 160 mm.
convex 5 MHz, 160 mm depth, PRF 0.8 kHz
What the research says
The evidence, four studies checked
- Palpation misses most thyroid nodules.
Among 2,441 people examined by both methods, physical examination found only 53 of the 249 nodules that high-resolution ultrasonography found, which is 21%.
Wiest et al., J Ultrasound Med 1998 - Ultrasound guidance more than halved inadequate thyroid samples.
Across 9,683 patients, specimens were cytologically inadequate in 8.7% of conventional aspirations against 3.5% of sonography-guided aspirations, and false negatives fell from 2.3% to 1%.
Danese et al., Thyroid 1998 - Sonographic risk scoring removed more than half the biopsies.
In 477 patients referred for aspiration, ACR TI-RADS classified 268 of 502 biopsies as unnecessary with a false-negative rate of 2.2%.
Grani et al., J Clin Endocrinol Metab 2019 - Ultrasound detects moderate to severe fatty liver against histology.
A meta-analysis of 49 studies and 4,720 participants reported 84.8% sensitivity and 93.6% specificity for moderate to severe fatty liver against histology.
Hernaez et al., Hepatology 2011
Pick your model
Pick the model that fits your day
The L14Pro runs 10/14 MHz across 256 elements and 64 channels, which is the frequency band the AIUM parameter prefers for the neck. Depth steps at 20, 40, 60 and 80 mm cover the gland and the deep cervical chain.
14 MHz, 256 elements, most chosen
$3,441 L14Pro · 10/14 MHz 256-Element LinearBuy nowView L14Pro →The D3Ultra carries linear, convex and phased heads in one 263 g body. The gland at 7.5/10 MHz and the liver at 3.2/5.0 MHz sit in one visit, and convex depth reaches 300 mm.
three heads, neck plus abdomen
$2,976 D3Ultra · Convex Linear Phased MultipuBuy nowVer D3Ultra →The L10H is the model whose attribute list adds visualized needle guidance to the puncture guide and needle enhance. A 40 mm footprint and a 5-hour battery suit a procedure list.
visualized needle guidance, needle work
$2,325 L10H · 7.5/10 MHz 192 Element LineaBuy nowView L10H →Comparativa de escáneres
Seven Suresult models for endocrine work, compared by frequency and depth
Swipe to see all columns →
| Modelo | Precio | Frecuencia | Profundidad | Lo mejor para |
|---|---|---|---|---|
| $3,441 | 10/14 MHz linear | 20/40/60/80 mm | The neck exam at 256 elements and 64 channels | |
| $2,139 | 10/14 MHz linear | 20 to 80 mm | The 10/14 MHz neck band on a 192-element head | |
| $3,720 | 16/20 MHz lineal | 20/30/40 mm | Very superficial detail in a slim neck | |
| $3,534 | 7.5/10 MHz linear | 20/40/60/100 mm | A 40 mm footprint for a large gland or goiter | |
| $2,325 | 7.5/10 MHz linear | 20/40/60/100 mm | Visualized needle guidance and a 5-hour battery | |
| $2,976 | Linear 7.5/10 MHz plus convex and phased 3.2/5.0 MHz | Linear 20 to 100 mm, convex 90 to 300 mm | Neck and abdomen on one 263 g probe | |
| $4,185 | Convex 3.2/5.0 MHz | 90 to 300 mm | Liver and kidney work at 256 elements |
Against the known brands
Suresult vs Clarius L15 HD3, Butterfly iQ3 and GE Vscan Air CL for thyroid work
Swipe to see all columns →
| Suresult | Clarius L15 HD3 | Mariposa iQ3 | GE Vscan Aire CL | |
|---|---|---|---|---|
| Frequency on the neck head | 10/14 MHz on the L14 and L14Pro, 16/20 MHz on the L20 models, 7.5/10 MHz on the L10 models | 5-15 MHz | 1-12 MHz single probe | 3-12 MHz on the linear array |
| Depth on that head | 20 to 80 mm on the L14 models and 20 to 100 mm on the L10 models | 7 cm | 6 cm on the Small Organ preset | 8 cm linear |
| Device price | $2,139 for the L14, $3,441 for the L14Pro, $2,976 for the D3Ultra | $3,795 | $3,899 | starting at $4,999 |
| Suscripción de software | None; Doppler, measurement and DICOM export sit on the scanner | Membership at $695/year, $1,785 for three years, or $2,500 one-time | Core at $299/year, Advanced at $420/year, or $1,500 for five years | Digital Tools sold separately from the device |
| Doppler on the device | Color, power and pulsed-wave Doppler with M-mode on every model on this page, with no membership | Color and power Doppler with the scanner; pulsed-wave Doppler with membership | Color Doppler in Core; power and pulsed-wave Doppler in Advanced | Color Doppler, pulsed-wave Doppler and M-mode |
| Guía de la aguja | In-plane and out-of-plane puncture guides on every model on this page. Needle enhance on the L14Pro, L20Pro, L10SH, L10H and D3Ultra. Visualized needle guidance on the L10H | Needle Enhance, included with membership only | Needle Viz and a Needle: Out-Of-Plane preset, in the Advanced plan | Not listed among the published Vscan Air CL modes: B-mode, color Doppler, pulsed-wave Doppler and M-mode |
| Plataformas | Windows, iOS and Android | iOS y Android | iOS y Android | iOS y Android |
| Landed cost | Shipping and import duties inside the checkout price, 1 to 7 day delivery | US list price; shipping and duties extra outside the US | US list price; shipping and duties extra outside the US | US list price; shipping and duties extra outside the US |
| Regulatory registrations | FDA 510(k) · ISO 13485 · EU MDR (CE) · TGA · ANVISA · Health Canada | FDA 510(k) | FDA 510(k) | FDA 510(k) |
- The L14 and L14Pro run at 14 MHz, inside the band the AIUM head and neck parameter prefers.
- Color Doppler, power Doppler, pulsed-wave Doppler and M-mode ship on every model on this page, with no membership.
- Measurement runs on the scanner, and one capture on this page carries 26.51 mm and 5.97 mm read off the app.
- The L10H attribute list adds visualized needle guidance for clinics doing their own guided aspirations.
- A biopsy needle guide for linear probes is a separate catalog item at $464.
- The D3Ultra puts a 7.5/10 MHz linear head and a convex head reaching 300 mm in one 263 g probe.
- DICOM export sits on the device, alongside JPEG, PNG and MP4 saving.
- Suresult Software runs on Windows as well as on iOS and Android.
- Shipping and import duties sit inside the checkout price, with delivery in 1 to 7 days.
Clarius publishes the L15 HD3 membership at $695 a year, which reaches $3,475 by year five on top of the $3,795 scanner. The L14Pro carries no software fee in any year.
Three models, one decision
One conversation gets a direct recommendation: the right Suresult probe, or a straight “neither.”
Top Handheld Ultrasounds for Thyroid, Parathyroid & Adrenal Imaging
L20Pro
L20Pro: ecógrafo lineal de alta frecuencia (16/20 MHz) para estética, piel y sistema musculoesquelético superficial
Frecuencia: 16/20 MHz
Profundidad de exploración: 20/30/40 mm
Endocrinología
D3Ultra
D3Ultra Ultrasonidos portátiles multifunción de fase lineal convexa
Frecuencia: Sonda convexa / en fase 3,2/5,0MHz Sonda lineal 7,5/10MHz
Profundidad de exploración: Lineal: 20-100mm, Convexa y en fase: 90-300 mm
Endocrinología
L14Pro
Sonda de ultrasonidos lineal L14Pro de 10/14 MHz y 256 elementos para el sistema musculoesquelético
Frecuencia: 14/10 MHz
Profundidad de exploración: 20/40/60/80 mm
Endocrinología
D3Pro
D3Pro Dual-Head 3-in-1 Wireless Ultrasound Scanner
Frecuencia: Sonda convexa/faseada 3,2/5,0MHz, Sonda lineal 7,5/10MHz
Profundidad de exploración: Palpador convexo/faseado: 90-305mm, Sonda lineal: 20-80mm
Endocrinología
L20
L20 Ultrasonidos inalámbricos lineales de alta frecuencia de 16/20 MHz para inyecciones de cirugía plástica facial y cutánea MSK
Frecuencia: 16/20 MHz
Profundidad de exploración: 10/20/30/40 mm
Endocrinología
CD2
CD2 Ultrasonidos lineales en fase de doble cabezal 192 elementos con Doppler color
Frecuencia: Sonda en fase 2,2/3,6MHz, Sonda lineal 7,5/10MHz
Profundidad de exploración: Sonda en fase: 90-190mm, Sonda lineal: 20-100mm
Endocrinología
D3L
D3L Sonda de Diagnóstico por Ultrasonidos 128 Elementos, Convexa Lineal Fasada 3 Modos
Frecuencia: Sonda convexa / en fase 3,2/5,0MHz Sonda lineal 7,5/10MHz
Profundidad de exploración: Palpador convexo/faseado: 90-305mm, Sonda lineal: 20-80mm
Endocrinología
D3
D3 Ultrasonido portátil de doble sonda lineal convexa en fase 3 en 1
Frecuencia: Lineal: 7,5/10 MHz, Convexa y en fase 3,2/5 MHz
Profundidad de exploración: Lineal: 20-100mm, Convexa y en fase: 90-305mm
Endocrinología
D2LM
Ecógrafo portátil D2LM - Microconvexo y lineal de doble sonda
Frecuencia: Sonda microconvexa 5/7MHz, Sonda lineal 10/12MHz
Profundidad de exploración: Microconvexo 60-160mm, Lineal 20-80mm
Endocrinología
L14
L14 Ultrasonidos lineales inalámbricos - Imágenes de alta frecuencia
Frecuencia: 14/10 MHz
Profundidad de exploración: 20-80 mm
Endocrinología
E11
E11 Sonda de ultrasonidos portátil microconvexa Doppler en color
Frecuencia: 8/11MHz
Profundidad de exploración: 30-80mm
Endocrinología
L10
L10 Ecógrafo lineal de 7,5/10MHz y 192 elementos con Doppler color
Frecuencia: 7,5/10MHz
Profundidad de exploración: 20-55mm
Qué tener en cuenta antes de comprar un ecógrafo portátil para endocrinología
Before you buy
Qué comprobar antes de comprar
What is the best handheld ultrasound for endocrinology?
For thyroid and neck work the Suresult L14Pro is the strongest fit, at 10/14 MHz across 256 elements. A practice that also scans the liver should take the D3Ultra, which adds a convex head reaching 300 mm.
What frequency does a thyroid ultrasound need?
The AIUM practice parameter for head and neck ultrasound states that mean frequencies of 10 to 14 MHz or greater are preferred for most patients. The Suresult L14 and L14Pro reach 14 MHz.
How deep does a thyroid scan need to reach?
The thyroid gland sits within the first 40 mm of the neck in most adults. Suresult neck captures were recorded at 40 mm and 55 mm of depth. The L14 models reach 80 mm for the deeper cervical chain.
How much does a thyroid ultrasound machine cost?
The Suresult L14 starts at $2,139 and the L14Pro at $3,441, with software included. The Clarius L15 HD3 lists at $3,795 and the Butterfly iQ3 at $3,899 before subscription fees.
Can a handheld ultrasound find a thyroid nodule?
Yes. The atlas on this page carries a cystic and solid nodule captured at 10 MHz on 55 mm of depth. A 1998 study of 2,441 people found that palpation identified only 21% of the nodules ultrasound found.
Does the same probe check cervical lymph nodes?
A Suresult linear probe images cervical lymph nodes at 10 MHz, and one capture measured 26.51 mm by 5.97 mm on screen. A second capture shows a node with an echogenic hilum through its center.
Can these scanners guide a thyroid fine-needle aspiration?
Every Suresult model on this page carries in-plane and out-of-plane puncture guides. Needle enhance is listed on the L14Pro, L20Pro, L10SH, L10H and D3Ultra, and the L10H adds visualized needle guidance. A biopsy needle guide for linear probes is sold as a separate item.
Is ultrasound guidance worth it for thyroid aspiration?
A study of 9,683 patients reported inadequate specimens in 8.7% of conventional aspirations and 3.5% of sonography-guided aspirations. False negatives fell from 2.3% to 1% in the same series.
Does the scanner support ACR TI-RADS scoring?
ACR TI-RADS scores a thyroid nodule from image features such as margin, echogenicity and punctate echogenic foci. A scanner therefore has to resolve those features at the gland. The published Suresult thyroid video on this page works a nodule through the ACR TI-RADS categories.
Can an endocrinologist check the liver with the same device?
Yes, if the device carries a convex head. The Suresult D3Ultra and the C5SH-Pro reach 300 mm at 3.2/5.0 MHz, and this page shows a fatty liver captured at 3.5 MHz on 200 mm of depth.
How accurate is ultrasound for fatty liver?
A 2011 meta-analysis in Hepatology pooled 49 studies and 4,720 participants. It reported 84.8% sensitivity and 93.6% specificity for moderate to severe fatty liver against histology.
Is there a subscription on a Suresult scanner?
No. Color Doppler, pulsed-wave Doppler, measurement and DICOM export sit on the device with no annual fee. Clarius publishes a $695 yearly membership and Butterfly publishes plans at $299 and $420 a year.
Does it export images into the patient record?
Yes. Every Suresult scanner on this page saves stills and cine loops of up to 1,000 frames, and exports as DICOM, JPEG, PNG or MP4.
Which platform does the software run on?
Suresult Software runs on Windows, iOS and Android. That matters in an endocrine clinic where the desk machine is a Windows laptop rather than a tablet.
Which Suresult model suits a thyroid clinic, a diabetes clinic or an aspiration list?
Thyroid and neck work: the L14Pro. Diabetes practice that also images the liver: the D3Ultra. Guided aspiration lists: the L10H, the model that lists visualized needle guidance.
Software libre,
Escaneados ilimitados
Los ecógrafos portátiles de Suresult incluyen un potente software que le ofrece funciones ilimitadas sin coste adicional. Disfrute de DICOM y doppler de onda pulsada gratuitos, además de una interfaz fácil de usar en iOS, Android y Windows, para que pueda centrarse en ofrecer una atención de máxima calidad sin ningún coste de software.
Capture cada detalle, guíe con precisión y comparta con facilidad
Mejore su flujo de trabajo de ecografía con nuestra solución todo en uno. Experimente la precisión, la sencillez y la eficiencia en cada exploración.
Más de 17 preajustes especializados
Sonda convexa/faseada
Sonda lineal
27 Mediciones automatizadas para diagnósticos precisos
Simplifique su trabajo con un completo conjunto de herramientas para realizar evaluaciones rápidas y en tiempo real.
Modo B
- Longitud, área/circunferencia, ángulo, trazo, distancia
- Depth and angle readouts for needle and injection guidance
- Obstetric biometrics (gestational age, EFW) when your caseload needs them
Modo B+M
- Frecuencia cardiaca, tiempo, distancia
- Diámetro interno del ventrículo izquierdo (DIVId, DIVIs)
- Fracción de eyección (FE), Volumen sistólico (VS)
Modo B+PW
- Velocidad, frecuencia cardíaca, relación S/D, profundidad
- Medición automática del caudal de los recipientes
- Velocidad sistólica máxima (PS), velocidad diastólica final (ED)
- Velocidad máxima promediada en el tiempo (TAMAX), velocidad media promediada en el tiempo (TAMEAN)
- Índice de Pulsatilidad (PI), Índice de Resistividad (RI)
- Diámetro del vaso (DIAM), Caudal (FL)
Bucle de cine
Graba hasta 1000 fotogramas (≈165 segundos) de movimiento continuo para captar todos los detalles sutiles.
Función de asistencia a la perforación
Disfrute precisa en el plano y guías fuera del plano para aumentar su confianza durante las intervenciones.
Exportación flexible de archivos
Guarda y comparte tus escaneos sin esfuerzo en JPEG, MP4, PNG o DICOM formatos, integrándose perfectamente en su flujo de trabajo.
Expert Guidance
Talk to a Scanner Specialist
Tell Suresult about your daily workflow and get a personal scanner recommendation with an all-inclusive quote.
- Free scanner-fit consultation — probes, frequency and depth matched to your procedures
- All-inclusive quote — shipping, customs clearance and applicable taxes covered
- Fast delivery — ships within 24 hours, 1–7 days door to door
- No se requiere ninguna suscripción de software — iOS, Android and Windows apps included
- 30-day returns and 24/7 support
Live chat opens right here — no forms, no waiting.
PREGUNTAS FRECUENTES
Si ya tiene formación en ecografía, puede empezar a utilizar Suresult inmediatamente, sin necesidad de una formación especial. Para los nuevos usuarios, un curso estándar de formación en POCUS suele ser suficiente para empezar a explorar con eficacia.
Absolutamente. El sistema ofrece herramientas de mejora de la aguja que muestran la trayectoria de la aguja en tiempo real, admitiendo tanto los abordajes en plano como fuera de plano.
Yes. Use the on-screen measurement tools to size a nodule during the live scan, then save labeled images or cine loops to the device. At follow-up visits, pull up prior scans for side-by-side comparison, so changes in size or appearance are easy to document and discuss with the patient.
Yes. Images and reports are stored in standard DICOM format. Once transferred to your connected device over Wi-Fi, you can easily upload them to most electronic medical record systems or PACS.
All Suresult devices are compact, wireless, and rugged—made for daily clinic use or mobile visits. Additionally, 1.5–3 hours of battery life and wireless charging make it practical for extended hours.
Sí. Viene precargado con preajustes optimizados para exploraciones de tiroides/paratiroides, vasos y órganos abdominales, lo que reduce la necesidad de realizar ajustes manuales.
Sí, los ecógrafos portátiles Suresult equipados con una sonda convexa son capaces de obtener imágenes de estructuras más profundas, como las glándulas suprarrenales. Los preajustes abdominales disponibles en la aplicación gratuita simplifican aún más el proceso, ayudándole a identificar hallazgos incidentales.