Handheld ultrasound for dermatology, from skin layers to the nail unit

This page shows eight dermatology captures taken on Suresult linear probes at 14, 18, 20 and 24 MHz, seven of them with the app header on screen. Entry to the specialty starts at $2,139 for the L14, and the 256-element L24Pro sits at $4,185.

The eight atlas captures on this page came off Suresult linear probes, and seven of them keep the full app header on screen. ·Trusted by 8,717 clinicians →

Resposta rápida

A dermatology ultrasound machine is a high-frequency linear scanner that resolves the epidermis, dermis, subcutis and nail unit at the bedside.

  • Suresult linear models step from 10/14 MHz up to 18/24 MHz, so a clinic can match frequency to the depth of the lesion it treats.
  • Suresult's published skin captures hold depth at 20 mm with compounding on, which is where the dermal layers separate cleanly.
  • Color Doppler and pulsed-wave Doppler ship on every Suresult high-frequency linear model, so a facial vessel can be found and then measured.
  • No Suresult scanner needs a software subscription, and Doppler is not held behind a membership tier.
Skin and subcutaneous layers in longitudinal B-mode on an L20Pro at 20 MHz, 20 mm depth, compounding on

The capture atlas

Eight real dermatology windows, captured on Suresult linear probes at 14 to 24 MHz

Unedited clinical captures · select any image to enlarge

Skin layers2 windows

Epidermis to hypodermis on the L20Pro

Epidermis to hypodermis on the L20Pro

The bright entry line, the dermal band beneath it and the darker subcutis all sit inside 20 mm of depth. This is the view a clinician sets gain against before measuring anything.

captured on an L20Pro at 20 MHz, 20 mm depth, gain 42 dB, dynamic range 60, compounding on, 5 June 2026
Subcutaneous fat lobules and septa on the L20Pro

Subcutaneous fat lobules and septa on the L20Pro

Fat lobules read as rounded gray islands separated by brighter fibrous septa. Septal thickening and lobule distortion are what a clinician looks for in panniculitis and in cellulite grading.

captured on an L20Pro at 20 MHz, 20 mm depth, gain 42 dB, dynamic range 60, compounding on, 5 June 2026

Cutaneous Doppler2 windows

Dermal and subcutaneous vessels in color Doppler

Dermal and subcutaneous vessels in color Doppler

A vessel fills red and blue inside the color box at 20 MHz, with two smaller signals below it. Finding the vessel before the needle goes in is the whole point of this window.

captured on an L20Pro at 20 MHz, 20 mm depth, color gain 69, steer 12 degrees, PRF 1.0 kHz, wall filter 3
Pulsed-wave trace on a superficial facial vessel

Pulsed-wave trace on a superficial facial vessel

The spectral trace reports peak systolic 15.73 cm/s, end diastolic 3.41 cm/s and a resistive index of 0.78, through a 1 mm sample gate. An arterial waveform reads differently from a vein before an injection.

captured on an L14 at 14 MHz, 40 mm depth, angle 55 degrees, PRF 2.0 kHz, by an aesthetic buyer who owns the L14 and the L14Pro

The nail unit2 windows

Nail plate, nail bed and distal phalanx at 24 MHz

Nail plate, nail bed and distal phalanx at 24 MHz

The nail plate shows as a bright double line, the nail bed as the softer band under it, and the phalanx as the bright floor. At 24 MHz the two plate layers stay separate.

captured on an L24Pro at 24 MHz, 20 mm depth, gain 70 dB, dynamic range 100, compounding on, 10 May 2026
Nail matrix and bed on the same L24Pro session

Nail matrix and bed on the same L24Pro session

The proximal end of the same nail unit, where the matrix sits under the proximal nail fold. Matrix involvement is what separates a nail-bed problem from a growth-plate problem.

captured on an L24Pro at 24 MHz, 20 mm depth, dynamic range 100, compounding on, 10 May 2026

Lesions and collections2 windows

Scalp soft-tissue collection at 18 MHz

Scalp soft-tissue collection at 18 MHz

A darker collection sits under the scalp dermis with the bright skin line intact above it. Depth and extent on screen decide whether a lesion is drained or treated medically.

captured on an L24Pro at 18 MHz, 25 mm depth, gain 70 dB, dynamic range 100, compounding on, 13 May 2026
Superficial lesion measured with color flow at its margin

Superficial lesion measured with color flow at its margin

Calipers cross a dark oval lesion while color Doppler marks flow at its edge. Size and vascularity together are what a clinician records before deciding to excise or watch.

captured on an L14 at 14 MHz with color Doppler and calipers, by an aesthetic buyer who owns both the L14 and the L14Pro
One nail unit at six frequencies, 10 MHz to 24 MHzUltrasound key frame

Select a card to switch capture

Technique basics

How the exam comes together, probe to report

  1. Take the highest frequency the depth allows.Take the highest frequency the depth allows.

    Skin and nail work sits in the top 25 mm, which is where 18/24 MHz on the L24Pro resolves best. Anything below 25 mm needs the L20 models or the L14.

    18/24 MHz reaches 25 mm; 16/20 MHz reaches 40 mm
  2. Hold depth at 20 mm and turn compounding on.Hold depth at 20 mm and turn compounding on.

    The skin captures on this page were taken at 20 mm with compounding on. Bringing depth down further stretches the layers but loses the fascial floor as a reference.

    D: 20 mm and Compound: ON on the L20Pro header
  3. Set gain low and dynamic range wide for layer contrast.Set gain low and dynamic range wide for layer contrast.

    The captures on this page run gain at 42 dB with dynamic range 60 on the L20Pro, and 70 dB with dynamic range 100 on the L24Pro. Too much gain floods the dermal band.

    GN 42 dB / DR 60 on the L20Pro; GN 70 dB / DR 100 on the L24Pro
  4. Add color, then put a number on the vessel.Add color, then put a number on the vessel.

    Color Doppler finds the vessel and pulsed-wave Doppler measures it, returning peak systolic velocity and a resistive index in the app. Both modes are on the scanner without a fee.

    PS, ED and RI read out in the app

What the research says

The evidence, three studies checked

  • Adding ultrasound raised diagnostic accuracy on skin lesions.

    In 4,338 skin ultrasound examinations, the referring clinical diagnosis was correct in 73% of lesions, and adding ultrasound raised that to 97%.

    Wortsman & Wortsman, J Am Acad Dermatol 2010
  • Presurgical ultrasound changed the surgical plan on facial basal cell carcinoma.

    Ultrasound detected two subclinical satellite lesions at the nose that changed the surgery plan, and tumor thickness matched histology with an intraclass correlation of 0.9.

    Bobadilla et al., Cancer Imaging 2008
  • Ultrasound found hidradenitis lesions that the clinical exam did not show.

    Among 34 patients with hidradenitis suppurativa, ultrasound showed subclinical fluid collections in 76.4% and fistulous tracts in 29.4% of patients.

    Wortsman et al., Dermatol Surg 2013

Pick your model

Pick the model that fits your day

MOST CHOSENSuresult L24ProA dermatology clinic doing lesions and nailsL24Pro

The L24Pro reaches 24 MHz across 256 elements, which is the frequency the nail captures on this page were taken at. Depth is fixed at 10, 15, 20 or 25 mm, matching where skin work lives.

24 MHz, 256 elements, highest frequency

$4,185 L24Pro · 18/24 MHz 256-Element AestheBuy nowView L24Pro →
Suresult L20ProAesthetic work mapping facial vesselsL20Pro

The L20Pro holds 16/20 MHz detail and still reaches 40 mm, so a facial vessel and the tissue plane under it stay in one frame. Color and pulsed-wave Doppler are on the probe.

20 MHz plus 40, aesthetics

$3,720 L20Pro · 16/20 MHz High-Frequency LinBuy nowView L20Pro →
Suresult L14Skin work is one exam among severalL14

The L14 runs 10/14 MHz out to 80 mm, which covers a lipoma or a deep collection that a 24 MHz head cannot reach. It is the entry point into this specialty at Suresult.

20 to 80 mm, entry

$2,139 L14 · Linear Wireless Ultrasound -Buy nowView L14 →

Comparação de scanners

Seven Suresult linear models for dermatology, compared by frequency and depth

Swipe to see all columns →

ModeloPreçoFrequênciaProfundidadeMelhor para
Suresult L24ProL24Pro$4,18518/24 MHz linear10/15/20/25 mmNail unit and dermal detail at 256 elements
Suresult L24L24$3,44118/24 MHz linear10/15/20/25 mmThe same 24 MHz ceiling at 192 elements
Suresult L20ProL20Pro$3,72016/20 MHz linear10/20/30/40 mmSkin plus 40 mm of subcutaneous reach, 256 elements
Suresult L20L20$2,79016/20 MHz linear10/20/30/40 mm20 MHz skin work at 192 elements
Suresult L14ProL14Pro$3,44110/14 MHz linear20/40/60/80 mmDeeper subcutaneous and facial vessel work, 256 elements
Suresult L14L14$2,13910/14 MHz linear20 to 80 mmEntry linear model for lesions deeper than 25 mm
Suresult L10SHL10SH$3,5347.5/10 MHz linear20/40/60/100 mmA 40 mm footprint for scanning large areas

Against the known brands

Suresult vs Clarius L20 HD3, Butterfly iQ3 and GE Vscan Air CL for dermatology

Swipe to see all columns →

SuresultClarius L20 HD3Butterfly iQ3GE Vscan Air CL
Top frequency on the skin head24 MHz on the L24Pro and L24; 20 MHz on the L20Pro and L2020 MHz (8-20 MHz range)12 MHz (1-12 MHz range)12 MHz on the linear array (3-12 MHz)
Superficial-setting depth10 to 25 mm on the L24 models, 10 to 40 mm on the L20 models, 20 to 80 mm on the L14 models4 cm1 to 12 cm on the MSK-Soft Tissue preset8 cm on the linear array
Device price$4,185 for the L24Pro, $3,720 for the L20Pro, $2,139 for the L14$5,395$3,899starting at $4,999
Assinatura de softwareNone; Doppler and DICOM export sit on the scannerEssentials at $695/year, $1,785 for three years, or $2,500 one-timeCore at $299/year, Advanced at $420/year, or $1,500 for five yearsDigital Tools sold separately from the device
Doppler modes on the deviceColor, power, pulsed-wave and M-mode on every model on this pageColor and power Doppler with the scanner; pulsed-wave Doppler inside the Essentials membershipColor, power and pulsed-wave inside the Advanced planDoppler colorido
PlatformsWindows, iOS and AndroidiOS and AndroidiOS and AndroidiOS and Android
Landed costShipping and import duties inside the checkout price, 1 to 7 day deliveryUS list price; shipping and duties extra outside the USUS list price; shipping and duties extra outside the USUS list price; shipping and duties extra outside the US
Regulatory registrationsFDA 510(k) · ISO 13485 · EU MDR (CE) · TGA · ANVISA · Health CanadaFDA 510(k)FDA 510(k)FDA 510(k)
Where Suresult wins
  • Six Suresult linear models run at 14 MHz or higher, and the L24Pro and L24 reach 24 MHz.
  • The L24Pro, L20Pro and L14Pro each carry 256 elements across 64 channels.
  • Color Doppler, power Doppler, pulsed-wave Doppler and M-mode ship on every Suresult model on this page with no membership.
  • DICOM export sits on the device, with MP4 and PNG saving alongside it.
  • Suresult Software runs on Windows as well as on mobile.
  • Cine loops hold up to 1,000 frames, so a nail or lesion sweep can be reviewed frame by frame.
  • Needle Enhance is on the L24Pro, L24, L20Pro, L20, L14Pro and L10SH, and the puncture guide overlay is on every linear model.
  • Shipping and import duties sit inside the checkout price.
  • Eight dermatology captures on this page came off Suresult probes at 14 to 24 MHz.
The five-year math

Clarius publishes its Essentials membership at $695 a year, which reaches $3,475 by year five on top of the $5,395 scanner. The L24Pro carries no software fee in any year.

L24Pro, paid once$4,185Clarius L20 HD3: scanner + membership$695$695$695$695$695= $3,475 in fees alone by year five

Three models, one decision

Not sure which model fits your cases?

One conversation gets a direct recommendation: the right Suresult probe, or a straight “neither.”

O melhor ultrassom portátil para dermatologia e lesões cutâneas

Designed for skin and soft tissue, our handheld device lets dermatologists detect, differentiate, and document lesions with clinical confidence in real time.
Sonda de ultrassom linear portátil Suresult L20Pro de 16/20 MHz com tela de tablet para Doppler colorido
Melhor escolha
L20Pro

L20Pro 16/20 MHz: Ultrassom linear de alta frequência para estética, pele e sistema músculo-esquelético superficial

Frequência: 16/20 MHz

Profundidade de varredura: 10/20/30/40 mm

Dermatologia

For skin layers, lesions or slightly deeper structures the L20Pro runs 16/20 MHz to 40 mm across 256 elements, with Doppler for vascular context. A 4-hour battery and wireless charging keep it on the bench through a derm clinic day.
buy scanner
Suresult L24Pro 18/24MHz handheld aesthetic ultrasound probe with superficial vessel Doppler screen
L24Pro

Sonda de ultrassom estética L24Pro de 18/24 MHz com 256 elementos para preenchimento

Frequência: 18/24 MHz

Profundidade de varredura: 10/15/20/25mm

Dermatologia

With 18/24MHz, the L24Pro delivers high resolution for skin lesions, layers, or subcutaneous abnormalities—perfect for guiding biopsies or injections. Doppler adds vascular detail for suspicious areas, and its 4-hour battery keeps it humming through clinic hours. Lightweight and wireless, it’s a derm’s high-res dream.
buy scanner
Sonda de ultrassom linear portátil Suresult L14Pro de 10/14 MHz com tela de tablet para Doppler vascular
Mais acessível
L14Pro

Sonda de ultrassom linear L14Pro de 10/14 MHz com 256 elementos para o sistema músculo-esquelético

Frequência: 10/14 MHz

Profundidade de varredura: 20/40/60/80 mm

Dermatologia

The L14Pro’s 10/14MHz frequency suits deeper skin structures or subcutaneous lesions—think biopsies or injections. Puncture guides and Doppler add utility, though it’s less high-res than the L20 or L24. At 145g, it’s a solid derm tool for mid-depth needs.
buy scanner

O que considerar antes de comprar um ultrassom portátil para dermatologia

Escolha o dispositivo ideal para pele e tecidos moles com sondas lineares de alta frequência e funcionalidade Doppler colorido.

Before you buy

O que verificar antes de comprar

What is the best handheld ultrasound for dermatology?

For skin and nail work the Suresult L24Pro is the strongest fit, at 18/24 MHz across 256 elements. Clinics that also scan below 25 mm should take the L20Pro instead.

What frequency does a skin ultrasound need?

Dermal and nail detail wants 18 MHz or higher. A Suresult buyer video compares one nail unit from 10 MHz to 24 MHz and labels 18 MHz at 256 elements the best setting for nail examination.

How deep does a dermatology ultrasound scan?

The Suresult L24 models reach 25 mm, the L20 models reach 40 mm and the L14 models reach 80 mm. Skin, nail and most facial soft tissue sit inside 25 mm.

How much does a dermatology ultrasound machine cost?

The Suresult L14 lists at $2,139 and the L24Pro at $4,185, with software included. The Clarius L20 HD3 lists at $5,395 before its membership fee.

Can a handheld ultrasound image the nail unit?

Yes. Suresult's published nail captures were taken on an L24Pro at 24 MHz and 20 mm depth. They separate the nail plate, nail bed, matrix and distal phalanx.

Can ultrasound measure how deep a skin tumor goes?

It measures thickness well. A 2008 study of facial basal cell carcinoma using a 7-15 MHz linear probe found an intraclass correlation of 0.9 between ultrasound thickness and histology.

Is a handheld ultrasound useful for facial filler work?

Yes, for finding vessels before the needle. A Suresult L14 pulsed-wave trace of a superficial facial vessel reported a peak systolic velocity of 15.73 cm/s and a resistive index of 0.78.

Which Suresult model suits an aesthetic clinic scanning faces?

The L20Pro. It holds 16/20 MHz detail and reaches 40 mm, so a superficial vessel and the plane beneath it stay in the same frame.

Does dermatology ultrasound replace a biopsy?

No. Ultrasound reports size, depth and vascularity, while histology reports the tissue diagnosis. Clinicians use the scan to plan the excision or the injection.

What are the limits of skin ultrasound?

Wortsman and Wortsman, in J Am Acad Dermatol 2010, reported that ultrasound cannot detect lesions that are epidermal only or measure less than 0.1 mm in depth. Their review covered 4,338 skin ultrasound examinations.

Does a Suresult scanner need a software subscription?

No. Doppler, measurements, needle guidance and DICOM export are on the device, and the Suresult app runs on Windows as well as on mobile.

What is the five-year cost against a Clarius L20 HD3?

Clarius publishes Essentials at $695 a year, which reaches $3,475 by year five on top of the $5,395 scanner. A Suresult scanner adds no software fee.

Can the scanner export images into a patient record?

Yes. Every Suresult linear model exports DICOM, JPEG, PNG and MP4, and stores studies locally on the connected device.

Can one probe cover both skin and deeper soft tissue?

The L20Pro comes closest, with 20 MHz detail and a 40 mm depth setting. A clinic that regularly scans past 40 mm needs the L14Pro alongside it.

Does ultrasound find hidradenitis lesions the exam misses?

Often. In 34 patients with hidradenitis suppurativa, ultrasound showed subclinical fluid collections in 76.4% and fistulous tracts in 29.4% of patients.

Software livre,
Varreduras ilimitadas

Os ultrassons portáteis da Suresult vêm com um software poderoso que lhe oferece recursos ilimitados sem custo adicional. Desfrute de DICOM e doppler de onda pulsada gratuitos, além de uma interface amigável no iOS, Android e Windows - para que o senhor possa se concentrar em oferecer atendimento de alta qualidade sem nenhuma taxa de software.

Suresult Aplicativo de ultrassom gratuito para Apple Android Windows

Compatível com toda a plataforma, vitalício Upgrades gratuitos

Capture todos os detalhes, guie com precisão e compartilhe com facilidade

Melhore seu fluxo de trabalho de ultrassom com nossa solução completa. Experimente a precisão, a simplicidade e a eficiência em cada exame.

Mais de 17 predefinições especializadas

Sonda convexa/faseada

AbdômenGinecologiaObstétricoCardíacoUrologiaRimPulmão

Sonda Linear

TireoidePelePeças pequenasPediatriaVascularCarótidaMamaMSKNervoFluxo do vaso

5 Modos de varredura

27 Medições automatizadas para diagnósticos precisos

Simplifique seu trabalho com um conjunto completo de ferramentas para avaliações rápidas e em tempo real.

Modo B

  • Comprimento, área/circunferência, ângulo, traço, distância
  • Depth and angle readouts for needle and injection guidance
  • Obstetric biometrics (gestational age, EFW) when your caseload needs them

Modo B+M

  • Frequência cardíaca, tempo, distância
  • Diâmetro interno do ventrículo esquerdo (LVIDd, LVIDs)
  • Fração de ejeção (EF), volume sistólico (SV)

Modo B+PW

  • Velocidade, frequência cardíaca, relação S/D, profundidade
  • Medição automática da vazão do vaso
  • Velocidade sistólica de pico (PS), velocidade diastólica final (ED)
  • Velocidade máxima com média de tempo (TAMAX), velocidade média com média de tempo (TAMEAN)
  • Índice de Pulsatilidade (PI), Índice Resistivo (RI)
  • Diâmetro do vaso (DIAM), fluxo (FL)

Cine Loop

Grave até 1000 quadros (≈165 segundos) de movimento contínuo para capturar cada detalhe sutil.

Função de assistência à perfuração

seringa

Aproveite com precisão no plano e guias fora do plano para aumentar sua confiança durante as intervenções.

Exportação flexível de arquivos

Salve e compartilhe suas digitalizações sem esforço em JPEG, MP4, PNG ou DICOM integrando-se perfeitamente ao seu fluxo de trabalho.

Suresult specialist guiding an ultrasound-led procedure

Expert Guidance

Talk to a Scanner Specialist

Tell Suresult about your daily workflow and get a personal scanner recommendation with an all-inclusive quote.

  • Free scanner-fit consultation — probes, frequency and depth matched to your procedures
  • All-inclusive quote — shipping, customs clearance and applicable taxes covered
  • Fast delivery — ships within 24 hours, 1–7 days door to door
  • Não é necessária nenhuma assinatura de software — iOS, Android and Windows apps included
  • 30-day returns and 24/7 support
Talk to an Expert

Live chat opens right here — no forms, no waiting.

PERGUNTAS FREQUENTES