Handheld ultrasound for dermatology, from skin layers to the nail unit

This page shows eight dermatology captures taken on Suresult linear probes at 14, 18, 20 and 24 MHz, seven of them with the app header on screen. Entry to the specialty starts at $2,139 for the L14, and the 256-element L24Pro sits at $4,185.

The eight atlas captures on this page came off Suresult linear probes, and seven of them keep the full app header on screen. ·Trusted by 8,717 clinicians →

簡単な回答

A dermatology ultrasound machine is a high-frequency linear scanner that resolves the epidermis, dermis, subcutis and nail unit at the bedside.

  • Suresult linear models step from 10/14 MHz up to 18/24 MHz, so a clinic can match frequency to the depth of the lesion it treats.
  • Suresult's published skin captures hold depth at 20 mm with compounding on, which is where the dermal layers separate cleanly.
  • Color Doppler and pulsed-wave Doppler ship on every Suresult high-frequency linear model, so a facial vessel can be found and then measured.
  • No Suresult scanner needs a software subscription, and Doppler is not held behind a membership tier.
Skin and subcutaneous layers in longitudinal B-mode on an L20Pro at 20 MHz, 20 mm depth, compounding on

The capture atlas

Eight real dermatology windows, captured on Suresult linear probes at 14 to 24 MHz

Unedited clinical captures · select any image to enlarge

Skin layers2 windows

Epidermis to hypodermis on the L20Pro

Epidermis to hypodermis on the L20Pro

The bright entry line, the dermal band beneath it and the darker subcutis all sit inside 20 mm of depth. This is the view a clinician sets gain against before measuring anything.

captured on an L20Pro at 20 MHz, 20 mm depth, gain 42 dB, dynamic range 60, compounding on, 5 June 2026
Subcutaneous fat lobules and septa on the L20Pro

Subcutaneous fat lobules and septa on the L20Pro

Fat lobules read as rounded gray islands separated by brighter fibrous septa. Septal thickening and lobule distortion are what a clinician looks for in panniculitis and in cellulite grading.

captured on an L20Pro at 20 MHz, 20 mm depth, gain 42 dB, dynamic range 60, compounding on, 5 June 2026

Cutaneous Doppler2 windows

Dermal and subcutaneous vessels in color Doppler

Dermal and subcutaneous vessels in color Doppler

A vessel fills red and blue inside the color box at 20 MHz, with two smaller signals below it. Finding the vessel before the needle goes in is the whole point of this window.

captured on an L20Pro at 20 MHz, 20 mm depth, color gain 69, steer 12 degrees, PRF 1.0 kHz, wall filter 3
Pulsed-wave trace on a superficial facial vessel

Pulsed-wave trace on a superficial facial vessel

The spectral trace reports peak systolic 15.73 cm/s, end diastolic 3.41 cm/s and a resistive index of 0.78, through a 1 mm sample gate. An arterial waveform reads differently from a vein before an injection.

captured on an L14 at 14 MHz, 40 mm depth, angle 55 degrees, PRF 2.0 kHz, by an aesthetic buyer who owns the L14 and the L14Pro

The nail unit2 windows

Nail plate, nail bed and distal phalanx at 24 MHz

Nail plate, nail bed and distal phalanx at 24 MHz

The nail plate shows as a bright double line, the nail bed as the softer band under it, and the phalanx as the bright floor. At 24 MHz the two plate layers stay separate.

captured on an L24Pro at 24 MHz, 20 mm depth, gain 70 dB, dynamic range 100, compounding on, 10 May 2026
Nail matrix and bed on the same L24Pro session

Nail matrix and bed on the same L24Pro session

The proximal end of the same nail unit, where the matrix sits under the proximal nail fold. Matrix involvement is what separates a nail-bed problem from a growth-plate problem.

captured on an L24Pro at 24 MHz, 20 mm depth, dynamic range 100, compounding on, 10 May 2026

Lesions and collections2 windows

Scalp soft-tissue collection at 18 MHz

Scalp soft-tissue collection at 18 MHz

A darker collection sits under the scalp dermis with the bright skin line intact above it. Depth and extent on screen decide whether a lesion is drained or treated medically.

captured on an L24Pro at 18 MHz, 25 mm depth, gain 70 dB, dynamic range 100, compounding on, 13 May 2026
Superficial lesion measured with color flow at its margin

Superficial lesion measured with color flow at its margin

Calipers cross a dark oval lesion while color Doppler marks flow at its edge. Size and vascularity together are what a clinician records before deciding to excise or watch.

captured on an L14 at 14 MHz with color Doppler and calipers, by an aesthetic buyer who owns both the L14 and the L14Pro
One nail unit at six frequencies, 10 MHz to 24 MHzUltrasound key frame

Select a card to switch capture

Technique basics

How the exam comes together, probe to report

  1. Take the highest frequency the depth allows.Take the highest frequency the depth allows.

    Skin and nail work sits in the top 25 mm, which is where 18/24 MHz on the L24Pro resolves best. Anything below 25 mm needs the L20 models or the L14.

    18/24 MHz reaches 25 mm; 16/20 MHz reaches 40 mm
  2. Hold depth at 20 mm and turn compounding on.Hold depth at 20 mm and turn compounding on.

    The skin captures on this page were taken at 20 mm with compounding on. Bringing depth down further stretches the layers but loses the fascial floor as a reference.

    D: 20 mm and Compound: ON on the L20Pro header
  3. Set gain low and dynamic range wide for layer contrast.Set gain low and dynamic range wide for layer contrast.

    The captures on this page run gain at 42 dB with dynamic range 60 on the L20Pro, and 70 dB with dynamic range 100 on the L24Pro. Too much gain floods the dermal band.

    GN 42 dB / DR 60 on the L20Pro; GN 70 dB / DR 100 on the L24Pro
  4. Add color, then put a number on the vessel.Add color, then put a number on the vessel.

    Color Doppler finds the vessel and pulsed-wave Doppler measures it, returning peak systolic velocity and a resistive index in the app. Both modes are on the scanner without a fee.

    PS, ED and RI read out in the app

What the research says

The evidence, three studies checked

  • Adding ultrasound raised diagnostic accuracy on skin lesions.

    In 4,338 skin ultrasound examinations, the referring clinical diagnosis was correct in 73% of lesions, and adding ultrasound raised that to 97%.

    Wortsman & Wortsman, J Am Acad Dermatol 2010
  • Presurgical ultrasound changed the surgical plan on facial basal cell carcinoma.

    Ultrasound detected two subclinical satellite lesions at the nose that changed the surgery plan, and tumor thickness matched histology with an intraclass correlation of 0.9.

    Bobadilla et al., Cancer Imaging 2008
  • Ultrasound found hidradenitis lesions that the clinical exam did not show.

    Among 34 patients with hidradenitis suppurativa, ultrasound showed subclinical fluid collections in 76.4% and fistulous tracts in 29.4% of patients.

    Wortsman et al., Dermatol Surg 2013

Pick your model

Pick the model that fits your day

MOST CHOSENSuresult L24ProA dermatology clinic doing lesions and nailsL24Pro

The L24Pro reaches 24 MHz across 256 elements, which is the frequency the nail captures on this page were taken at. Depth is fixed at 10, 15, 20 or 25 mm, matching where skin work lives.

24 MHz, 256 elements, highest frequency

$4,185 L24Pro · 18/24 MHz 256-Element AestheBuy nowView L24Pro →
Suresult L20ProAesthetic work mapping facial vesselsL20Pro

The L20Pro holds 16/20 MHz detail and still reaches 40 mm, so a facial vessel and the tissue plane under it stay in one frame. Color and pulsed-wave Doppler are on the probe.

20 MHz plus 40, aesthetics

$3,720 L20Pro · 16/20 MHz High-Frequency LinBuy nowView L20Pro →
Suresult L14Skin work is one exam among severalL14

The L14 runs 10/14 MHz out to 80 mm, which covers a lipoma or a deep collection that a 24 MHz head cannot reach. It is the entry point into this specialty at Suresult.

20 to 80 mm, entry

$2,139 L14 · Linear Wireless Ultrasound -Buy nowView L14 →

スキャナーの比較

Seven Suresult linear models for dermatology, compared by frequency and depth

Swipe to see all columns →

モデル価格頻度深さ最適
Suresult L24ProL24Pro$4,18518/24 MHz linear10/15/20/25 mmNail unit and dermal detail at 256 elements
Suresult L24L24$3,44118/24 MHz linear10/15/20/25 mmThe same 24 MHz ceiling at 192 elements
Suresult L20ProL20Pro$3,72016/20 MHz linear10・20・30・40 mmSkin plus 40 mm of subcutaneous reach, 256 elements
シュアサルト L20L20$2,79016/20 MHz linear10・20・30・40 mm20 MHz skin work at 192 elements
Suresult L14ProL14Pro$3,44110/14 MHz linear20・40・60・80 mmDeeper subcutaneous and facial vessel work, 256 elements
Suresult L14L14$2,13910/14 MHz linear20 to 80 mmEntry linear model for lesions deeper than 25 mm
Suresult L10SHL10SH$3,5347.5/10 MHz linear20/40/60/100 mmA 40 mm footprint for scanning large areas

Against the known brands

Suresult vs Clarius L20 HD3, Butterfly iQ3 and GE Vscan Air CL for dermatology

Swipe to see all columns →

スレクラリアス L20 HD3バタフライiQ3GE Vscan Air CL
Top frequency on the skin head24 MHz on the L24Pro and L24; 20 MHz on the L20Pro and L2020 MHz (8-20 MHz range)12 MHz (1-12 MHz range)12 MHz on the linear array (3-12 MHz)
Superficial-setting depth10 to 25 mm on the L24 models, 10 to 40 mm on the L20 models, 20 to 80 mm on the L14 models4 cm1 to 12 cm on the MSK-Soft Tissue preset8 cm on the linear array
Device price$4,185 for the L24Pro, $3,720 for the L20Pro, $2,139 for the L14$5,395$3,899starting at $4,999
Software subscriptionNone; Doppler and DICOM export sit on the scannerEssentials at $695/year, $1,785 for three years, or $2,500 one-timeCore at $299/year, Advanced at $420/year, or $1,500 for five yearsDigital Tools sold separately from the device
Doppler modes on the deviceColor, power, pulsed-wave and M-mode on every model on this pageColor and power Doppler with the scanner; pulsed-wave Doppler inside the Essentials membershipColor, power and pulsed-wave inside the Advanced planカラードップラー
PlatformsWindows, iOS and AndroidiOSおよびAndroidiOSおよびAndroidiOSおよびAndroid
Landed costShipping and import duties inside the checkout price, 1 to 7 day deliveryUS list price; shipping and duties extra outside the USUS list price; shipping and duties extra outside the USUS list price; shipping and duties extra outside the US
Regulatory registrationsFDA 510(k) · ISO 13485 · EU MDR (CE) · TGA · ANVISA · Health CanadaFDA 510(k)FDA 510(k)FDA 510(k)
Where Suresult wins
  • Six Suresult linear models run at 14 MHz or higher, and the L24Pro and L24 reach 24 MHz.
  • The L24Pro, L20Pro and L14Pro each carry 256 elements across 64 channels.
  • Color Doppler, power Doppler, pulsed-wave Doppler and M-mode ship on every Suresult model on this page with no membership.
  • DICOM export sits on the device, with MP4 and PNG saving alongside it.
  • Suresult Software runs on Windows as well as on mobile.
  • Cine loops hold up to 1,000 frames, so a nail or lesion sweep can be reviewed frame by frame.
  • Needle Enhance is on the L24Pro, L24, L20Pro, L20, L14Pro and L10SH, and the puncture guide overlay is on every linear model.
  • Shipping and import duties sit inside the checkout price.
  • Eight dermatology captures on this page came off Suresult probes at 14 to 24 MHz.
The five-year math

Clarius publishes its Essentials membership at $695 a year, which reaches $3,475 by year five on top of the $5,395 scanner. The L24Pro carries no software fee in any year.

L24Pro, paid once$4,185Clarius L20 HD3: scanner + membership$695$695$695$695$695= $3,475 in fees alone by year five

Three models, one decision

Not sure which model fits your cases?

One conversation gets a direct recommendation: the right Suresult probe, or a straight “neither.”

皮膚科学と皮膚病変のためのトップハンドヘルド超音波

Designed for skin and soft tissue, our handheld device lets dermatologists detect, differentiate, and document lesions with clinical confidence in real time.
Suresult L20Pro 16/20MHz ハンドヘルドリニア超音波プローブ(カラードップラー対応タブレット画面付き)
ベストチョイス
L20Pro

L20Pro 16/20 MHz 高周波リニア超音波装置(美容、皮膚、および表在性筋骨格系用)

頻度: 16/20 MHz

スキャンの深さ 10・20・30・40 mm

皮膚科学

For skin layers, lesions or slightly deeper structures the L20Pro runs 16/20 MHz to 40 mm across 256 elements, with Doppler for vascular context. A 4-hour battery and wireless charging keep it on the bench through a derm clinic day.
buy scanner
Suresult L24Pro 18/24MHz handheld aesthetic ultrasound probe with superficial vessel Doppler screen
L24Pro

L24Pro 18/24 MHz 256エレメント フィラー用美顔超音波プローブ

頻度: 18/24 MHz

スキャンの深さ 10/15/20/25mm

皮膚科学

With 18/24MHz, the L24Pro delivers high resolution for skin lesions, layers, or subcutaneous abnormalities—perfect for guiding biopsies or injections. Doppler adds vascular detail for suspicious areas, and its 4-hour battery keeps it humming through clinic hours. Lightweight and wireless, it’s a derm’s high-res dream.
buy scanner
Suresult L14Pro 10/14MHz ハンドヘルドリニア超音波プローブ(血管ドップラー機能付き、タブレット画面対応)
最も手頃な価格
L14Pro

L14Pro 10/14 MHz 256-Element Linear Ultrasound Probe for MSK

頻度: 10/14 MHz

スキャンの深さ 20・40・60・80 mm

皮膚科学

The L14Pro’s 10/14MHz frequency suits deeper skin structures or subcutaneous lesions—think biopsies or injections. Puncture guides and Doppler add utility, though it’s less high-res than the L20 or L24. At 145g, it’s a solid derm tool for mid-depth needs.
buy scanner

皮膚科用ハンドヘルド超音波を購入する前に考慮すべきこと

高周波リニアプローブとカラードプラ機能を備えた皮膚・軟部組織用の理想的な装置をお選びください。

Before you buy

購入前のチェックポイント

What is the best handheld ultrasound for dermatology?

For skin and nail work the Suresult L24Pro is the strongest fit, at 18/24 MHz across 256 elements. Clinics that also scan below 25 mm should take the L20Pro instead.

What frequency does a skin ultrasound need?

Dermal and nail detail wants 18 MHz or higher. A Suresult buyer video compares one nail unit from 10 MHz to 24 MHz and labels 18 MHz at 256 elements the best setting for nail examination.

How deep does a dermatology ultrasound scan?

The Suresult L24 models reach 25 mm, the L20 models reach 40 mm and the L14 models reach 80 mm. Skin, nail and most facial soft tissue sit inside 25 mm.

How much does a dermatology ultrasound machine cost?

The Suresult L14 lists at $2,139 and the L24Pro at $4,185, with software included. The Clarius L20 HD3 lists at $5,395 before its membership fee.

Can a handheld ultrasound image the nail unit?

Yes. Suresult's published nail captures were taken on an L24Pro at 24 MHz and 20 mm depth. They separate the nail plate, nail bed, matrix and distal phalanx.

Can ultrasound measure how deep a skin tumor goes?

It measures thickness well. A 2008 study of facial basal cell carcinoma using a 7-15 MHz linear probe found an intraclass correlation of 0.9 between ultrasound thickness and histology.

Is a handheld ultrasound useful for facial filler work?

Yes, for finding vessels before the needle. A Suresult L14 pulsed-wave trace of a superficial facial vessel reported a peak systolic velocity of 15.73 cm/s and a resistive index of 0.78.

Which Suresult model suits an aesthetic clinic scanning faces?

The L20Pro. It holds 16/20 MHz detail and reaches 40 mm, so a superficial vessel and the plane beneath it stay in the same frame.

Does dermatology ultrasound replace a biopsy?

No. Ultrasound reports size, depth and vascularity, while histology reports the tissue diagnosis. Clinicians use the scan to plan the excision or the injection.

What are the limits of skin ultrasound?

Wortsman and Wortsman, in J Am Acad Dermatol 2010, reported that ultrasound cannot detect lesions that are epidermal only or measure less than 0.1 mm in depth. Their review covered 4,338 skin ultrasound examinations.

Does a Suresult scanner need a software subscription?

No. Doppler, measurements, needle guidance and DICOM export are on the device, and the Suresult app runs on Windows as well as on mobile.

What is the five-year cost against a Clarius L20 HD3?

Clarius publishes Essentials at $695 a year, which reaches $3,475 by year five on top of the $5,395 scanner. A Suresult scanner adds no software fee.

Can the scanner export images into a patient record?

Yes. Every Suresult linear model exports DICOM, JPEG, PNG and MP4, and stores studies locally on the connected device.

Can one probe cover both skin and deeper soft tissue?

The L20Pro comes closest, with 20 MHz detail and a 40 mm depth setting. A clinic that regularly scans past 40 mm needs the L14Pro alongside it.

Does ultrasound find hidradenitis lesions the exam misses?

Often. In 34 patients with hidradenitis suppurativa, ultrasound showed subclinical fluid collections in 76.4% and fistulous tracts in 29.4% of patients.

フリーソフト、
無制限スキャン

Suresultのハンドヘルド超音波診断装置には、追加費用なしで無制限の機能を提供する強力なソフトウェアが付属しています。無料のDICOMとパルス波ドップラーに加え、iOS、Android、Windowsのユーザーフレンドリーなインターフェースをお楽しみください。

アップル、アンドロイド、ウィンドウズのためのSuresult無料超音波アプリ

フルプラットフォーム対応、ライフタイム 無料アップグレード

細部まで撮影、正確にガイド、簡単に共有

オールインワンソリューションで超音波検査のワークフローを改善します。すべてのスキャンで、正確さ、シンプルさ、効率性を実感してください。

17以上の専門プリセット

コンベックス / フェーズドプローブ

腹部婦人科産科心臓泌尿器科腎臓

リニアプローブ

甲状腺皮膚スモールパーツ小児科血管頸動脈乳房多発性硬化症神経容器の流れ

5 スキャンモード

27 精密診断のための自動測定

迅速でリアルタイムな評価のためのツール一式で作業を簡素化します。

Bモード

  • 長さ、面積/円周、角度、トレース、距離
  • Depth and angle readouts for needle and injection guidance
  • Obstetric biometrics (gestational age, EFW) when your caseload needs them

B+Mモード

  • 心拍数、時間、距離
  • 左室内径(LVIDd、LVIDs)
  • 駆出率(EF)、ストローク量(SV)

B+PWモード

  • 速度、心拍数、S/D比、深度
  • 自動容器流量測定
  • 収縮期ピーク速度(PS)、拡張末期速度(ED)
  • 時間平均最大速度(TAMAX)、時間平均平均平均速度(TAMEAN)
  • 脈動指数(PI)、抵抗指数(RI)
  • 容器直径(DIAM)、流量(FL)

シネループ

最大記録 1000フレーム(≒165秒) 微妙なディテールまでとらえる連続的な動き。

パンクアシスト機能

注射器

正確にお楽しみください 面内 そして 面外ガイド 介入時の自信を高めるために

柔軟なファイルエクスポート

でスキャンしたデータを簡単に保存、共有できます。 JPEG、MP4、PNG、またはDICOM フォーマットで、ワークフローとシームレスに統合できます。

Suresult specialist guiding an ultrasound-led procedure

Expert Guidance

Talk to a Scanner Specialist

Tell Suresult about your daily workflow and get a personal scanner recommendation with an all-inclusive quote.

  • Free scanner-fit consultation — probes, frequency and depth matched to your procedures
  • All-inclusive quote — shipping, customs clearance and applicable taxes covered
  • Fast delivery — ships within 24 hours, 1–7 days door to door
  • ソフトウェアのサブスクリプションは不要です — iOS, Android and Windows apps included
  • 30-day returns and 24/7 support
Talk to an Expert

Live chat opens right here — no forms, no waiting.

よくあるご質問