Handheld breast ultrasound machines, from the survey sweep to the needle
Five unedited breast captures from Suresult wireless linear hardware: a hypoechoic nodule at 40 mm with the color box placed over it, and two ten-second sweeps to the pectoral plane. Seven models compared on frequency and array footprint, the L14 at $2,139, software included and no subscription.
簡単な回答
A breast ultrasound machine is a high-frequency linear scanner that images breast tissue, so a clinician can characterize a palpable lump at the bedside.
- The American College of Radiology asks for a center frequency of at least 12 MHz in breast ultrasound. The Suresult L14 and L14Pro run 10 and 14 MHz settings.
- Color Doppler and pulsed-wave Doppler run on every Suresult linear model on this page, with the velocity scale and color gain printed on the frame.
- In-plane and out-of-plane puncture guides sit in the app on every Suresult linear model. Needle enhance is listed on the L14Pro, L20, L20Pro, L10SH, L10H and D3Ultra, and the L10H adds visualized needle guidance.
- Depth reaches 80 mm on the L14Pro and 100 mm on the L10SH, which puts the retromammary plane and the chest wall inside the field.

The capture atlas
Five real breast captures on Suresult wireless linear hardware, with two nodal windows beside them
Unedited clinical captures · select any image to enlarge
Focal lesion3 windows

Hypoechoic breast nodule at 40 mm depth
A well circumscribed oval nodule sits inside the glandular layer, wider than it is tall, with the fibrous planes running above and below it. The header reads harmonic 10 MHz, gain 68 dB, dynamic range 70.
captured at 40 mm depth, harmonic 10 MHz, gain 68 dB, dynamic range 70; frame 100 of 100 in the saved loop. On-screen header fields are demo entries. The file records the wireless linear probe family, not a specific model.
Color box placed over the same nodule
The color region of interest is drawn tight around the lesion at 7.5 MHz with the velocity scale at plus or minus 12.3 cm/s. No internal flow is displayed in this frozen frame.
same study, 14 seconds after the B-mode frame; 7.5 MHz, 40 mm depth, color gain 172, steer 0
Color Doppler picks up two superficial vessels beside the lesion
Red and blue pixels sit at the upper left corner of the color box, in tissue separate from the nodule, and the nodule itself carries no signal. The scale is plus or minus 12.3 cm/s at 7.5 MHz with color gain 172.
same study, 43 seconds before the B-mode frame; 7.5 MHz, 40 mm depth, gain 68 dBTissue sweep2 clips

Ten-second breast tissue sweep to 55 mm
The clip runs through the fibroglandular layer and down onto the pectoral muscle, so the whole tissue thickness stays in the field. The header reads harmonic 10 MHz, gain 87 dB, dynamic range 60.
10-second clip at 10 fps, 864 x 656; 55 mm depth, harmonic 10 MHz, enhancement 4. Header fields are demo entries.
Second sweep through the same breast
The second clip crosses denser fibrous septa and shows the layers separating as the probe moves. Settings match the first sweep at 55 mm and harmonic 10 MHz.
10-second clip recorded 30 seconds after the first; 55 mm depth, gain 87 dB, dynamic range 60Nodal windows2 cards

Superficial lymph node with an echogenic hilum
A hypoechoic node shows a bright central hilum and a thin even cortex. This capture is a cervical node, and the same linear head reads axillary nodes against the same landmarks.
cervical node from the same clinical reference library, not an axillary capture; wireless linear head, superficial preset
Second node, cortex read against hilum
The bright hilar line runs through the middle of the node with no focal cortical bulge. Cortical thickness is what a breast clinician checks once a lesion has been found.
cervical node from the same clinical reference library, not an axillary capture; wireless linear head, superficial preset
▶Select a card to switch capture
Technique basics
How the exam comes together, probe to report
Choose the linear head by frequency first.The American College of Radiology asks for a center frequency of at least 12 MHz for breast ultrasound. The L14 and L14Pro run 10/14 MHz, and the L20 series runs 16/20 MHz for shallower targets.
at least 12 MHz, ACR
Check the footprint against the survey you actually do.The L14Pro and L20Pro carry a 25 mm array, while the L10SH and L10H carry 40 mm and the L10W carries 80 mm. A wider array covers a quadrant in fewer passes.
25 mm, 40 mm or 80 mm
Turn harmonic imaging on, then set depth to the chest wall.The two breast sweeps on this page ran harmonic imaging at 10 MHz and 55 mm of depth, which keeps the pectoral plane in the field. The frozen nodule frame beside this step sits at 40 mm, after the depth came back.
F: H10.0MHz, D: 40 mm
Draw the color box around the lesion, not the whole field.A tight color region of interest holds the frame rate up and keeps the velocity scale readable. The atlas frames ran the scale at plus or minus 12.3 cm/s with color gain 172 at 7.5 MHz.
scale ±12.3 cm/s
Set the needle path before the needle enters.The Suresult app carries in-plane and out-of-plane puncture guides, plus a grid and a placeable target with an on-screen radius. Needle enhance is listed on the L14Pro, L20, L20Pro, L10SH, L10H and D3Ultra.
app panel shown on a carotid preset, not a breast scan
Fit the reusable guide when the angle has to be fixed.The reusable linear needle guide clamps onto the probe and is detented at 40, 50 and 60 degrees. It is listed at $464 and fits the linear models on this page.
40, 50 and 60 degree detents
What the research says
The evidence, three studies checked
- Portable handheld ultrasound found breast cancer on its own.
A 2019 meta-analysis of 26 studies restricted to portable handheld ultrasound reported a pooled sensitivity of 80.1% and a pooled specificity of 88.4% for breast cancer detection.
Sood et al., J Glob Oncol 2019 - Adding ultrasound to mammography raised sensitivity and lowered specificity.
In 72,998 Japanese women aged 40 to 49, adjunctive ultrasonography raised sensitivity to 91.1% from 77.0%, while specificity fell to 87.7% from 91.4%.
Ohuchi et al., Lancet 2016 - Ultrasound-guided core biopsy agreed with the surgical specimen.
Across 94 breast lesions, ultrasound-guided core needle biopsy matched surgical histology in 96.8% of cases, with sensitivity of 98.6% and a false-negative rate of 1.3%.
Mocian et al., Chirurgia (Bucur) 2018
Pick your model
Pick the model that fits your day
A breast clinic that wants one survey headL14ProThe L14Pro runs 10/14 MHz on 256 elements and 64 channels, with depth steps to 80 mm that keep the chest wall in the field. The American College of Radiology asks for a center frequency of at least 12 MHz in breast ultrasound.
10/14 MHz, 256 elements, survey default
$3,441 L14Pro · 10/14 MHz 256-Element LinearBuy nowView L14Pro →
Superficial lesions, skin and scarsL20ProThe L20Pro runs 16/20 MHz on 256 elements with depth steps of 10, 20, 30 and 40 mm. That band resolves a shallow lesion and the dermis above it, and stops short of the retromammary plane.
16/20 MHz on 256, resolution first
$3,720 L20Pro · 16/20 MHz High-Frequency LinBuy nowView L20Pro →
Aspiration and core sampling, wider headL10HThe L10H is the one Suresult linear model whose attributes list visualized needle guidance, on a 40 mm array with depth to 100 mm. Its 5600 mAh battery gives 5 hours of continuous scanning.
visualized needle guidance, needle work
$2,325 L10H · 7.5/10 MHz 192 Element LineaBuy nowView L10H →スキャナーの比較
Seven Suresult linear models for breast work, compared
Swipe to see all columns →
| モデル | 価格 | 頻度 | 深さ | 最適 |
|---|---|---|---|---|
L14Pro | $3,441 | 10/14 MHz | 20・40・60・80 mm | Breast survey at 10/14 MHz, 256 elements and 64 channels |
L14 | $2,139 | 10/14 MHz | 20 to 80 mm | Entry into the same frequency band on 192 elements |
L20Pro | $3,720 | 16/20 MHz | 10・20・30・40 mm | Shallow lesions and the dermis above them, 256 elements |
L20 | $2,790 | 16/20 MHz | 10・20・30・40 mm | The same 16/20 MHz band on 192 elements |
L10SH | $3,534 | 7.5/10 MHz | 20/40/60/100 mm | 40 mm array and 256 elements for quadrant survey and deep tissue |
L10H | $2,325 | 7.5/10 MHz | 20/40/60/100 mm | Visualized needle guidance, 40 mm array, 5 hours of scanning |
D3Ultra | $2,976 | Linear 7.5/10 MHz, convex 3.2/5.0 MHz, phased 3.2/5.0 MHz | Linear 20/40/60/100 mm | Breast as one exam among several, with abdomen and cardiac on the same probe |
Against the known brands
Suresult vs Clarius L15 HD3, Clarius L20 HD3 and Butterfly iQ3 for breast imaging
Swipe to see all columns →
| スレ | クラリアス L15 HD3 | クラリアス L20 HD3 | バタフライiQ3 | |
|---|---|---|---|---|
| 頻度 | L14 and L14Pro 10/14 MHz, L20 and L20Pro 16/20 MHz, L10SH and L10H 7.5/10 MHz | 5 to 15 MHz | 8 to 20 MHz | 1 to 12 MHz |
| Published depth | 80 mm on the L14Pro, 100 mm on the L10SH and L10H, 40 mm on the L20 series | 7 cm | 4 cm | Small organs preset to 6 cm, deep abdomen preset to 30 cm |
| Array footprint | 80 mm on the L10W, 40 mm on the L10SH and L10H, 25 mm on the L14Pro and L20Pro | Field of view 50 mm | Field of view 25 mm | Butterfly publishes no array footprint; the probe housing measures 152 x 52 x 37 mm |
| Device price | L14 $2,139, L14Pro $3,441, L20Pro $3,720, software included | $3,795 | $5,395 | $3,899 |
| ソフトウェア使用料 | No required subscription; Windows, Android and iOS included | Essentials membership $695 per year, or $2,500 one-time | Essentials membership $695 per year, or $2,500 one-time | Core $299 per year, Advanced $420 per year, or $1,500 one-time for 5 years |
| Scanner weight | 145 g on the L14Pro and L20Pro, 150 g on the L10SH, 200 g on the L10H | 290 g | 290 g | 300 g |
| 針誘導 | In-plane and out-of-plane puncture guides on every Suresult linear model, with no membership. Needle enhance on the L14Pro, L20, L20Pro, L10SH, L10H and D3Ultra, and visualized needle guidance on the L10H | Needle Enhance, included in the paid Essentials membership | Needle Enhance, included in the paid Essentials membership | Needle Viz and Needle: Out-of-Plane presets |
| Landed cost | Duties and shipping inside the checkout price, 1 to 7 day delivery | US list price, duties and shipping extra outside the US | US list price, duties and shipping extra outside the US | US list price, duties and shipping extra outside the US |
| Regulatory registrations | FDA 510(k) · ISO 13485 · EU MDR (CE) · TGA · ANVISA · Health Canada | FDA 510(k) | FDA 510(k) | FDA 510(k) |
- Five breast captures on this page are unedited clinical files, with gain, depth and frequency left on the frame.
- The L14 and L14Pro run 10/14 MHz, and the American College of Radiology asks for a center frequency of at least 12 MHz in breast ultrasound.
- The L10SH and L10H carry a 40 mm array and the L10W carries 80 mm, so quadrant survey takes fewer passes.
- Depth reaches 100 mm on the L10SH and L10H, which covers the retromammary plane and the chest wall.
- In-plane and out-of-plane puncture guides ship on every Suresult linear model, with needle enhance on the L14Pro, L20, L20Pro, L10SH, L10H and D3Ultra.
- No membership fee is required to keep Suresult software running on Windows, Android or iOS.
- The linear probes on this page weigh 145 g to 250 g and charge wirelessly or over USB; the D3Ultra weighs 263 g and charges wirelessly.
- Duties and shipping sit inside the checkout price, with 1 to 7 day delivery.
Clarius lists Essentials membership at $695 per year, which reaches $3,475 in fees by year five on top of the $3,795 scanner. The store also lists a $2,500 one-time membership and a $1,785 three-year option. Suresult software carries no required subscription.
Three models, one decision
One conversation gets a direct recommendation: the right Suresult probe, or a straight “neither.”
乳房の画像診断と治療に最適なハンドヘルド超音波装置
L20Pro
L20Pro 16/20 MHz 高周波リニア超音波装置(美容、皮膚、および表在性筋骨格系用)
頻度: 16/20 MHz
スキャンの深さ 10・20・30・40 mm
乳房ケア
D3Ultra
D3Ultra凸型リニアフェーズド多目的ハンドヘルド超音波
頻度: コンベックス/フェーズドプローブ 3.2/5.0MHz リニアプローブ 7.5/10MHz
スキャンの深さ リニア:20-100mm、コンベックス&フェーズド:90-300mm
乳房ケア
L14Pro
L14Pro 10/14 MHz 256-Element Linear Ultrasound Probe for MSK
頻度: 10/14 MHz
スキャンの深さ 20・40・60・80 mm
乳房ケア
D3プロ
D3Pro Dual-Head 3-in-1 Wireless Ultrasound Scanner
頻度: コンベックス/フェーズドプローブ3.2/5.0MHz、リニアプローブ7.5/10MHz
スキャンの深さ コンベックス/フェーズドプローブ:90-305mm、リニアプローブ:20-80mm
乳房ケア
L20
L20高周波16/20 MHzリニアワイヤレス超音波(MSK皮膚・顔面形成外科注射用
頻度: 16/20 MHz
スキャンの深さ 10/20/30/40mm
乳房ケア
D3L
D3L 超音波診断の調査 128 の要素、凸の線形段階的な 3 モード
頻度: コンベックス/フェーズドプローブ 3.2/5.0MHz リニアプローブ 7.5/10MHz
スキャンの深さ コンベックス/フェーズドプローブ:90-305mm、リニアプローブ:20-80mm
乳房ケア
D3
1つの手持ち型超音波に付きD3デュアルプローブ線形凸面フェーズ3
頻度: リニア:7.5/10 MHz、コンベックス&フェーズド3.2/5 MHz
スキャンの深さ リニア:20-100mm、コンベックス&フェーズド:90-305mm
乳房ケア
D2LM
D2LMハンドヘルド超音波 - マイクロコンベックス&リニアデュアルプローブ
頻度: マイクロコンベックスプローブ5/7MHz、リニアプローブ10/12MHz
スキャンの深さ マイクロコンベックス60-160mm、リニア20-80mm
乳房ケア
L14
L14 リニアワイヤレス超音波 - 高周波イメージング
頻度: 10/14 MHz
スキャンの深さ 20~80mm
乳房ケア
L10
色のドップラーが付いている L10 7.5/10MHz 192 の要素の線形超音波の走査器
頻度: 7.5/10MHz
スキャンの深さ 20-55mm
What to Consider Before Buying a Handheld Ultrasound for Breast Imaging
Before you buy
購入前のチェックポイント
What is the best handheld ultrasound machine for breast imaging?
The Suresult L14Pro runs 10/14 MHz on 256 elements with depth steps to 80 mm, which covers a breast survey and the chest wall.
What frequency should a breast ultrasound probe use?
The American College of Radiology states that transducers should be operated at a center frequency of at least 12 MHz, and preferably higher. Suresult publishes 10/14 MHz for the L14Pro and 16/20 MHz for the L20Pro.
How much does a breast ultrasound machine cost?
Suresult prices each linear model separately: the L14 at $2,139, the L14Pro at $3,441 and the L20Pro at $3,720, software included. Clarius lists the L15 HD3 at $3,795 and the L20 HD3 at $5,395.
Can a handheld ultrasound detect breast cancer?
A 2019 meta-analysis of 26 studies restricted to portable handheld ultrasound reported pooled sensitivity of 80.1% and specificity of 88.4% for breast cancer detection.
Does breast ultrasound replace mammography?
No. Mammography is the screening test with proven mortality benefit, and ultrasound is used alongside it or in settings where mammography is unavailable.
How much does adding ultrasound to mammography change detection?
In the J-START trial of 72,998 women aged 40 to 49, adjunctive ultrasonography raised sensitivity to 91.1% from 77.0%, and specificity fell to 87.7% from 91.4%.
Can these models guide a breast biopsy?
Yes. Every Suresult linear model carries in-plane and out-of-plane puncture guides, and needle enhance is listed on the L14Pro, L20, L20Pro, L10SH, L10H and D3Ultra. A reusable linear needle guide is listed at $464.
How accurate is ultrasound-guided core needle biopsy of the breast?
Across 94 breast lesions, ultrasound-guided core needle biopsy agreed with surgical histology in 96.8% of cases, with a false-negative rate of 1.3%.
Why does the probe footprint matter for breast scanning?
A wider array covers more tissue per sweep. The L10SH and L10H measure 40 mm across the array, against 25 mm on the L14Pro.
Can these models show color Doppler inside a breast lesion?
Yes, Suresult linear models run Color Doppler and pulsed-wave Doppler on a placeable region of interest. The two breast frames on this page show no flow inside the lesion, which is itself a reportable finding.
Can the same probe check the axilla?
Yes. The linear head that images the breast also images superficial lymph nodes, and depth to 100 mm on the L10SH and L10H reaches through axillary fat.
Is there a software subscription?
No. Suresult software for Windows, Android and iOS carries no required subscription. Clarius lists Essentials membership at $695 per year.
Does it export images into a patient record?
Yes. Every Suresult linear model exports JPEG, PNG, MP4 and DICOM, and stores cine loops of 100, 200, 500 or 1000 frames.
Which model suits a mobile or visiting breast clinic?
The L10H runs 5 hours of continuous scanning on a 5600 mAh battery and lists visualized needle guidance, which suits a clinician who scans away from a base.
Is automated breast volume scanning available on a handheld?
No. Suresult handheld models are two-dimensional linear scanners with Doppler. Automated breast volume scanning is a cart-based technology and is not offered here.
What depth should the scan start at?
A breast sweep starts at about 55 mm of depth, which keeps the pectoral plane in the field; depth is reduced once the lesion is centered.
What do competing handhelds charge for software each year?
Clarius lists Essentials membership at $695 per year or $2,500 one-time. Butterfly lists Core at $299 per year and Advanced at $420 per year.
フリーソフト、
無制限スキャン
Suresultのハンドヘルド超音波診断装置には、追加費用なしで無制限の機能を提供する強力なソフトウェアが付属しています。無料のDICOMとパルス波ドップラーに加え、iOS、Android、Windowsのユーザーフレンドリーなインターフェースをお楽しみください。
細部まで撮影、正確にガイド、簡単に共有
オールインワンソリューションで超音波検査のワークフローを改善します。すべてのスキャンで、正確さ、シンプルさ、効率性を実感してください。
17以上の専門プリセット
コンベックス / フェーズドプローブ
リニアプローブ
27 精密診断のための自動測定
迅速でリアルタイムな評価のためのツール一式で作業を簡素化します。
Bモード
- 長さ、面積/円周、角度、トレース、距離
- Depth and angle readouts for needle and injection guidance
- Obstetric biometrics (gestational age, EFW) when your caseload needs them
B+Mモード
- 心拍数、時間、距離
- 左室内径(LVIDd、LVIDs)
- 駆出率(EF)、ストローク量(SV)
B+PWモード
- 速度、心拍数、S/D比、深度
- 自動容器流量測定
- 収縮期ピーク速度(PS)、拡張末期速度(ED)
- 時間平均最大速度(TAMAX)、時間平均平均平均速度(TAMEAN)
- 脈動指数(PI)、抵抗指数(RI)
- 容器直径(DIAM)、流量(FL)
シネループ
最大記録 1000フレーム(≒165秒) 微妙なディテールまでとらえる連続的な動き。
パンクアシスト機能
正確にお楽しみください 面内 そして 面外ガイド 介入時の自信を高めるために
柔軟なファイルエクスポート
でスキャンしたデータを簡単に保存、共有できます。 JPEG、MP4、PNG、またはDICOM フォーマットで、ワークフローとシームレスに統合できます。

Expert Guidance
Talk to a Scanner Specialist
Tell Suresult about your daily workflow and get a personal scanner recommendation with an all-inclusive quote.
- Free scanner-fit consultation — probes, frequency and depth matched to your procedures
- All-inclusive quote — shipping, customs clearance and applicable taxes covered
- Fast delivery — ships within 24 hours, 1–7 days door to door
- ソフトウェアのサブスクリプションは不要です — iOS, Android and Windows apps included
- 30-day returns and 24/7 support
Live chat opens right here — no forms, no waiting.
よくあるご質問
また、コンパクトなボディとリアルタイムの画像処理により、病変の断端確認や手技のガイドなど、術中の使用に最適です。
はい、Suresult超音波システムは高精細造影画像を特徴とし、診断精度を高めるために造影された組織を鮮明に可視化することができます。
基本的な超音波の知識は役に立ちますが、当社の装置は直感的に使用できるように設計されており、乳房撮影用のプリセットが用意されているので、初めての方にも経験のある方にも最適です。
もちろんです。優れたコントラスト分解能で、エコーテクスチャー(低エコー、高エコー、等エコー)や病変の形態を解析することができます。
Yes. With secure wired and wireless/Wi-Fi transfer and DICOM support, you can upload scans to PACS or EMRs easily.