Handheld ultrasound for neurology, from the median nerve to the transtemporal window
Eight neurology windows captured by buyers on their own handhelds, with the on-screen frequency, depth and measurement left in the frame. Published pricing, software included, and no subscription attached to any model.
Quick answer
A neurology ultrasound machine images peripheral nerves and neck vessels with a high-frequency linear head, and reads flow through the temporal bone with a low-frequency sector head.
- Nerve work runs on a linear head: the L14Pro images at 10/14 MHz with 256 elements and reaches 80 mm.
- Carotid and vertebral studies use the same linear format at 7.5/10 MHz, where the D3Ultra reaches 100 mm.
- The transtemporal window needs a low-frequency sector head, and the CD2 phased array runs 2.2/3.6 MHz to 190 mm.
- Pulsed-wave Doppler, power Doppler, M-mode, calipers and DICOM export ship on every model on this page with no subscription.

The capture atlas
Eight neurology windows, captured by buyers on their own handhelds
Unedited clinical captures · select any image to enlarge
2 windows2 windows

Median nerve area at the wrist on the D3Ultra
The nerve is traced in short axis at the wrist and the app returns the area and circumference on screen. The frame reads 0.07 cm2, which sits under the 9.5 to 10.5 mm2 band pooled in the carpal tunnel meta-analysis below.
captured on a D3Ultra at H10.0 MHz, D 20 mm, GN 62 dB, DR 80, compound on. Area reads 0.07 cm2 and circumference 12.43 mm. Submitted by Enrique Botia Paniagua, 16 July 2026.
Interscalene brachial plexus on the D3Ultra
The nerve roots sit as dark rounded structures stacked between the anterior and middle scalene muscles. This is the window that follows an upper-limb nerve proximally when the lesion is not at the wrist or elbow.
captured on a D3Ultra at H10.0 MHz, D 40 mm, GN 54 dB, DR 40, compound off; submitted by Dr. Walter Rebmann, 22 June 20262 windows2 windows

Distal sciatic nerve in the posterior thigh
The distal sciatic nerve is shown in short axis with the in-plane needle guide drawn across the frame. The guide reads its own position and angle, which is how an injection or a diagnostic block is planned.
captured on a D3Ultra with the in-plane guide at position -19.5 mm and angle -58 degrees; submitted by David Heimpel, 15 August 2026
Saphenous nerve in the adductor canal
The adductor canal is imaged on the medial thigh with the femoral vessels and the saphenous nerve inside the sartorial fascia. The same window answers questions about saphenous neuropathy after knee surgery.
captured on a D3Ultra with the in-plane guide at position -19.5 mm and angle -40 degrees; submitted by David Heimpel, 15 August 20263 windows3 windows

Common carotid intima-media thickness on the D3Ultra
The far wall of the distal common carotid is measured with a single caliper pair, reading 0.65 mm. Intima-media thickness is the first number a stroke clinic takes before it looks for plaque.
captured on a D3Ultra at 7.5 MHz, D 40 mm, GN 58 dB, DR 100, compound on; length 0.65 mm; submitted by Enrique Botia Paniagua, 16 July 2026
Right internal carotid stenosis from soft plaque
Power Doppler fills the residual lumen in red while the soft plaque stays gray beneath it. The caliper runs the length of the soft plaque and reads 20.41 mm, and the German on-screen note calls it a long soft plaque.
captured on a D3Ultra at H10.0 MHz, D 60 mm, PDI gain 100, steer 12.0, PRF 4.0 K, wall filter 15; length 20.41 mm; submitted by Dr. Walter Rebmann, 18 October 2025
Plaque measured inside the right internal carotid
The same artery in B-mode carries three caliper measurements across the stenosis region, at 4.58 mm, 8.97 mm and 8.44 mm. Measuring on a frozen frame is what turns a bedside look into a record entry.
captured on a D3Ultra at H10.0 MHz, D 40 mm, GN 70 dB, DR 70, compound on; on-screen note reads ACI re Stenosebereich; submitted by Dr. Walter Rebmann, 8 December 20251 window1 window

Transtemporal midbrain with pulsed-wave Doppler of the right posterior cerebral artery
A 2.2 MHz sector head reaches the midbrain through the temporal bone at 130 mm depth, and the sample gate sits on the right posterior cerebral artery. The trace returns peak systolic 48.17 cm/s, end diastolic 22.32 cm/s, RI 0.54 and PI 0.83.
captured by a neurologist on an SD1 sector probe at 2.2 MHz, D 130 mm, GN 105 dB, DR 110. Gate 5 mm, angle -35 degrees, PRF 4.0 K. Submitted by Enrique Botia Paniagua, 16 July 2026. The SD1 is a TodoPocus-branded single sector probe and is not a Suresult catalog model.
▶Select a card to switch capture
Technique basics
How the exam comes together, probe to report
Start on the linear head at 10 to 14 MHz.A peripheral nerve exam begins with the highest frequency that still reaches the nerve. The L14Pro runs 10/14 MHz over a 25 mm footprint, which suits the median nerve at the wrist and the ulnar nerve at the elbow.
L14Pro: 10/14 MHz, depth 20/40/60/80 mm
Trace the nerve in short axis and read the area.Freeze the frame where the nerve is roundest, then trace inside the hyperechoic rim. The app returns cross-sectional area and circumference on screen, so the number goes into the note without a separate calculation.
On screen: D 20 mm, F H10.0 MHz, area 0.07 cm2
Follow the nerve proximally to the plexus.Slide up the limb and keep the nerve in short axis until the roots appear between the scalene muscles. Comparing caliber along the course is what separates a focal entrapment from a diffuse neuropathy.
On screen: D 40 mm, GN 54 dB, DR 40
Switch to Doppler for the neck vessels.Power Doppler shows where flow stops at a plaque, and pulsed-wave Doppler puts a velocity on the narrowed segment. Both run on the same linear head that just imaged the nerve.
On screen: PDI gain 100, PRF 4.0 K, wall filter 15
What the research says
The evidence, four studies checked
- Median nerve area near 10 mm2 pooled 84% sensitivity for carpal tunnel syndrome.
Across 11 of the 13 pooled studies, a median nerve cross-sectional area of 9.5 to 10.5 mm2 gave pooled sensitivity 0.84 and specificity 0.78. The authors placed sonography alongside electrodiagnostic testing rather than in place of it.
Descatha et al., Semin Arthritis Rheum 2012 - A four-nerve ultrasound score separated CIDP from AIDP with 90% sensitivity.
The Bochum ultrasound score sums cross-sectional area at four sites, including the ulnar nerve in Guyon's canal and the sural nerve. Under blinded evaluation it distinguished CIDP from AIDP with 90% sensitivity and 90.4% specificity.
Kerasnoudis et al., Clin Neurophysiol 2014 - A peak systolic velocity of 200 cm/s identified 70% carotid stenosis with 90% sensitivity.
A meta-analysis compared color duplex ultrasound with angiography in internal carotid stenosis. A peak systolic velocity of at least 200 cm/s detected 70% stenosis with 90% sensitivity and 94% specificity. At 130 cm/s for 50% stenosis, sensitivity was 98% and specificity 88%.
Jahromi et al., J Vasc Surg 2005 - Optic nerve sheath ultrasound detected raised intracranial pressure with 90% pooled sensitivity.
A 2011 meta-analysis pooled six studies and 231 patients that compared optic nerve sheath ultrasound with invasive intracranial pressure monitoring. Pooled sensitivity was 0.90 and pooled specificity was 0.85.
Dubourg et al., Intensive Care Med 2011
Pick your model
Pick the model that fits your day
Neuromuscular and nerve clinicsL14ProThe L14Pro carries 256 elements and 64 channels on a 25 mm footprint at 10/14 MHz, which is the format nerve cross-sectional area is measured in. Depth steps to 80 mm, so the sciatic nerve in the thigh stays reachable.
256 elements, one probe
$3,441 L14Pro · 10/14 MHz 256-Element LinearBuy nowView L14Pro →
Stroke and vascular neurologyD3UltraThe D3Ultra carries linear, convex and phased formats in one 263 g probe, and its linear head runs 7.5/10 MHz to 100 mm. Seven of the eight windows in the atlas above were captured on it.
three formats, one probe
$2,976 D3Ultra · Convex Linear Phased MultipuBuy nowD3Ultra 보기 →
Neurocritical care and the skull baseCD2The CD2 pairs a 7.5/10 MHz linear head for nerve and neck work with a 2.2/3.6 MHz phased head that reaches 190 mm. That is the lowest sector frequency published in the Suresult attribute tables, which is what a transtemporal window asks for.
2.2 MHz sector, dual head
$2,697 CD2 · Phased Linear Dual-Head UltrBuy nowView CD2 →
A first nerve probe on a tight budgetL14The L14 runs the same 10/14 MHz band on 192 elements and 64 channels, with color, power and pulsed-wave Doppler included. It covers median, ulnar and common peroneal work without a subscription.
10/14 MHz, entry linear
$2,139 L14 · Linear Wireless Ultrasound -Buy nowView L14 →Scanner comparison
Six Suresult models for neurology, compared by what each window needs
Swipe to see all columns →
| 모델 | 가격 | 빈도 | 깊이 | 최상의 대상 |
|---|---|---|---|---|
L14Pro | $3,441 | Linear 10/14 MHz | 20/40/60/80 mm | Nerve cross-sectional area on 256 elements and 64 channels |
L14 | $2,139 | Linear 10/14 MHz | 20 to 80 mm | Entry nerve imaging on 192 elements |
L20Pro | $3,720 | Linear 16/20 MHz | 10/20/30/40 mm | Small superficial nerves and digital branches at 20 MHz |
L10SH | $3,534 | Linear 7.5/10 MHz | 20/40/60/100 mm | A 40 mm footprint for plexus and carotid sweeps |
D3Ultra | $2,976 | Linear 7.5/10, convex 3.2/5.0, phased 3.2/5.0 MHz | Linear to 100 mm, phased to 300 mm | Nerve, neck vessels and lung on one 192-element probe |
CD2 | $2,697 | Linear 7.5/10 MHz, phased 2.2/3.6 MHz | Linear to 100 mm, phased 90 to 190 mm | The lowest sector frequency published in the attribute tables, at 150 g |
Against the known brands
Suresult vs Clarius L15 HD3, Butterfly iQ3 and GE Vscan Air CL for neurology
Swipe to see all columns →
| 결과 | 클라리우스 L15 HD3 | 버터플라이 iQ3 | GE Vscan Air CL | |
|---|---|---|---|---|
| Nerve imaging | 10/14 MHz to 80 mm on the L14Pro and 16/20 MHz to 40 mm on the L20Pro, 256 elements on both | 5-15 MHz linear, 7 cm maximum depth | 1-12 MHz single probe; the Nerve preset runs to 8 cm | Linear array 3-12 MHz to 8 cm |
| Neck vessels | 7.5/10 MHz linear to 100 mm on the D3Ultra and L10SH, with color, power and pulsed-wave Doppler included | 5-15 MHz linear, 7 cm maximum depth | 1-12 MHz single probe | Linear array 3-12 MHz to 8 cm, curved array 2-5 MHz to 24 cm |
| Sector head on the same body | The CD2 carries a 2.2/3.6 MHz phased head and a 7.5/10 MHz linear head in one 150 g body, reaching 190 mm | PA HD3 is a separate scanner, listed at $3,795 | The same single probe under a cardiac preset | Sector array sits on the SL model, a different probe from the CL |
| Measurements and export | Area, circumference and distance calipers, 100 to 1000 frame cine loops, and JPEG, PNG, MP4 and DICOM export on every model on this page | Advanced software packages sit inside the annual membership | Basic DICOM (PACS/MWL) is listed as available for purchase | Digital Tools are licensed separately from the device |
| Device price | $2,139 to $3,720, published | $3,795 published | $3,899 published | Starting at $4,999 published |
| 구독 | None. Software, Doppler, measurements, needle guides and DICOM export are included. | Clarius Essentials $695 per year | Core $299 per year, Advanced $420 per year, or $1,500 once for five years | Digital Tools sold separately from the device |
| Landed cost | Shipping, customs clearance, duties and taxes included at checkout; 1 to 7 business days in Europe, North America and Oceania | US list price; duties and shipping extra outside the US | US list price; duties and shipping extra outside the US | US list price; duties and shipping extra outside the US |
| Platforms | iOS, Android and Windows | iOS 및 Android | iOS 및 Android | iOS 및 Android |
| Regulatory registrations | FDA 510(k) · ISO 13485 · EU MDR (CE) · TGA · ANVISA · Health Canada | FDA 510(k) | FDA 510(k) | FDA 510(k) |
- Eight neurology windows on this page are unedited buyer captures, with the frequency, depth and measurement still on screen.
- Area, circumference and distance calipers are on every model on this page, so a nerve cross-sectional area is read in the app.
- No subscription: color Doppler, power Doppler, pulsed-wave Doppler, M-mode, needle guides and DICOM export are included.
- The L14Pro and L20Pro each carry 256 elements and 64 channels on a 25 mm footprint.
- The CD2 phased head reaches 2.2 MHz, the lowest sector frequency published in the Suresult attribute tables.
- Windows runs the same software as iOS and Android, so a clinic laptop can drive the probe.
- The checkout price includes shipping, customs clearance, duties and taxes, with delivery estimated at 1 to 7 business days in Europe, North America and Oceania.
- Registrations cover FDA 510(k), ISO 13485, EU MDR (CE), TGA, ANVISA and Health Canada, with the certificates published in the Suresult document library.
Clarius lists the L15 HD3 at $3,795 and Clarius Essentials at $695 per year, which reaches $3,475 in membership fees alone by year five. Butterfly lists the iQ3 at $3,899 with an Advanced plan at $420 per year, or $1,500 once for five years. The L14Pro carries no subscription, and its software, Doppler and DICOM export are included from day one.
Three models, one decision
One conversation gets a direct recommendation: the right Suresult probe, or a straight “neither.”
Top Handheld Ultrasound for Spine and Brain Imaging
D3Ultra
D3초볼록 선형 위상 다목적 핸드헬드 초음파
빈도: 볼록형/위상 조절형 프로브 3.2/5.0MHz 선형 프로브 7.5/10MHz
스캔 깊이: 선형: 20~100mm, 볼록 및 위상 조절형: 90~300mm
신경학
D3Pro
D3Pro Dual-Head 3-in-1 Wireless Ultrasound Scanner
빈도: 볼록형/위상 조절형 프로브 3.2/5.0MHz, 선형 프로브 7.5/10MHz
스캔 깊이: 볼록/위상 프로브: 90~305mm, 선형 프로브: 20~80mm
신경학
D3L
D3L 초음파 진단 프로브 128 소자, 볼록 선형 위상 3 모드
빈도: 볼록형/위상 조절형 프로브 3.2/5.0MHz 선형 프로브 7.5/10MHz
스캔 깊이: 볼록/위상 프로브: 90~305mm, 선형 프로브: 20~80mm
신경학
D3
D3 듀얼 프로브 선형 볼록 위상 3 in 1 핸드헬드 초음파
빈도: Linear: 7.5/10 MHz, Convex & Phased 3.2/5 MHz
스캔 깊이: Linear: 20-100mm, Convex & Phased: 90-305mm
신경학
L10
L10 7.5/10MHz 192 Elements Linear Ultrasound Scanner with Color Doppler
빈도: 7.5/10MHz
스캔 깊이: 20-55mm
What to Consider Before Buying a Handheld Ultrasound for Neurology
Before you buy
구매 전 확인해야 할 사항
What is the best handheld ultrasound for neurology?
For nerve work the Suresult L14Pro is the strongest fit, with 10/14 MHz on 256 elements and area calipers built into the app. For a clinic that also scans carotids and lungs, the D3Ultra carries linear, convex and phased formats in one probe.
Which probe format images peripheral nerves?
A linear array is the format for peripheral nerves, because nerves sit between 5 mm and 60 mm deep and need high frequency. Suresult linear models run from 7.5/10 MHz up to 18/24 MHz, and a nerve exam usually starts at 10 to 14 MHz.
Can a handheld ultrasound measure median nerve cross-sectional area?
Yes. A buyer capture on a Suresult D3Ultra shows a median nerve traced in short axis at the wrist. The app returned 0.07 cm2 of area and 12.43 mm of circumference on screen. The measurement is taken on a frozen frame and saved with the image.
Does nerve ultrasound replace nerve conduction studies?
No. A 2012 meta-analysis of 13 studies, 11 of them at the 9.5 to 10.5 mm2 threshold, examined median nerve cross-sectional area in carpal tunnel syndrome. Its authors concluded that sonography could not replace electrodiagnostic testing, but could give complementary results. Ultrasound adds structure and site of lesion where electrodiagnosis gives function.
How much does a neurology ultrasound machine cost?
A Suresult linear handheld for nerve work costs $2,139 to $3,720, with software, Doppler and DICOM export included. Clarius lists the L15 HD3 at $3,795 plus $695 per year, and Butterfly lists the iQ3 at $3,899 plus a plan from $299 per year.
Can a handheld ultrasound do a carotid duplex study?
Yes, within the limits of a focused study. The linear head carries B-mode, color, power and pulsed-wave Doppler. A 2005 meta-analysis found that a peak systolic velocity of at least 200 cm/s identified 70% stenosis with 90% sensitivity and 94% specificity.
Can a handheld ultrasound reach the transtemporal window?
Yes, with a sector head running near 2 MHz. The Suresult CD2 phased head runs 2.2/3.6 MHz to 190 mm, which is the format the transtemporal window asks for. A buyer capture on a 2.2 MHz sector probe shows the midbrain at 130 mm with a pulsed-wave trace of the right posterior cerebral artery.
Which Suresult model has the lowest sector frequency?
The CD2 has the lowest sector frequency published in the Suresult attribute tables. Its phased head runs 2.2/3.6 MHz to a depth of 190 mm, and it pairs with a 7.5/10 MHz linear head in the same 150 g body. The PD1 phased head runs 2.5/2.8/3.6 MHz, and the D3 family phased heads run 3.2/5.0 MHz.
Can a handheld measure optic nerve sheath diameter?
Optic nerve sheath diameter is measured on a high-frequency linear head about 3 mm behind the globe. Dubourg et al., Intensive Care Med 2011 pooled six studies and 231 patients, reporting 90% sensitivity and 85% specificity against invasive intracranial pressure monitoring. Orbital scanning should follow the ophthalmic acoustic output limits that apply where you practice.
Which frequency does small-nerve imaging need?
Digital nerves, the superficial radial nerve and small cutaneous branches sit within 10 mm to 20 mm of the skin. The L20Pro runs 16/20 MHz with 10 to 40 mm of depth, which is the band for those structures.
Does the scanner export a nerve study into the record?
Yes. Every Suresult model on this page saves stills and cine loops of 100 to 1000 frames, and exports JPEG, PNG, MP4 and DICOM. A nerve or carotid study reaches the record from the app without a cart system.
Is a subscription required to use the software?
No. Suresult software runs on iOS, Android and Windows with no annual fee. Color Doppler, pulsed-wave Doppler, measurements, needle guides and DICOM export are included on every model on this page.
Which model suits a neuromuscular clinic that also runs injections?
The L14Pro suits a neuromuscular clinic that also runs injections. It adds needle enhancement to the in-plane and out-of-plane guides, so a nerve is measured and then injected on the same probe. Buyer captures on a Suresult D3Ultra show the same guide overlay at the sciatic nerve and the adductor canal.
How long does the battery last on a clinic list?
The L14Pro holds a 4400 mAh battery rated for 4 hours of continuous scanning, and charges over USB or a wireless pad. The L10H holds 5600 mAh and is rated for 5 hours.
자유 소프트웨어,
무제한 스캔
Suresult의 휴대용 초음파 기기에는 추가 비용 없이 무제한 기능을 제공하는 강력한 소프트웨어가 탑재되어 있습니다. iOS, Android, Windows에서 무료 DICOM 및 펄스 도플러 기능을 이용할 수 있을 뿐만 아니라 사용자 친화적인 인터페이스까지 제공되므로, 소프트웨어 비용 부담 없이 최고 수준의 진료에 전념할 수 있습니다.
모든 디테일을 포착하고, 정밀하게 안내하며, 손쉽게 공유하세요
당사의 올인원 솔루션으로 초음파 검사 워크플로우를 개선하세요. 매번의 검사에서 정밀함, 간편함, 효율성을 직접 경험해 보세요.
17개 이상의 특수 프리셋
볼록 / 위상 조절 프로브
선형 프로브
정밀한 진단을 위한 27가지 자동 측정법
신속하고 실시간 평가를 위한 완벽한 도구 세트로 업무를 간소화하세요.
B-모드
- 길이, 면적/둘레, 각도, 선분, 거리
- Depth and angle readouts for needle and injection guidance
- Obstetric biometrics (gestational age, EFW) when your caseload needs them
B+M 모드
- 심박수, 시간, 거리
- 좌심실 내경 (LVIDd, LVIDs)
- 박출 분율(EF), 박출량(SV)
B+PW 모드
- 속도, 심박수, S/D 비율, 수심
- 선박 유량 자동 측정
- 최대 수축기 속도(PS), 이완기 말기 속도(ED)
- 시간 평균 최대 속도(TAMAX), 시간 평균 평균 속도(TAMEAN)
- 맥동 지수(PI), 저항 지수(RI)
- 선박 직경 (DIAM), 유량 (FL)
시네 루프
최대 1000 프레임 (≈165초) 미묘한 디테일 하나하나까지 포착하기 위한 연속적인 움직임.
펑크 지원 기능
정밀함을 만끽하세요 면 내 그리고 면외 가이드 중재 과정에서 자신감을 높이기 위해.
유연한 파일 내보내기
스캔한 파일을 손쉽게 저장하고 공유하세요. JPEG, MP4, PNG 또는 DICOM 다양한 형식을 지원하며, 사용자의 워크플로우와 원활하게 연동됩니다.

Expert Guidance
Talk to a Scanner Specialist
Tell Suresult about your daily workflow and get a personal scanner recommendation with an all-inclusive quote.
- Free scanner-fit consultation — probes, frequency and depth matched to your procedures
- All-inclusive quote — shipping, customs clearance and applicable taxes covered
- Fast delivery — ships within 24 hours, 1–7 days door to door
- No required software subscription — iOS, Android and Windows apps included
- 30-day returns and 24/7 support
Live chat opens right here — no forms, no waiting.
자주 묻는 질문
Yes. With the low-frequency phased array probe (like Suresult CD2) and Doppler modes, you can perform TCD assessments to monitor cerebral blood flow, especially in stroke, vasospasm, or trauma cases.
Absolutely. Suresult devices feature real-time needle tracking, making them perfect for ultrasound-guided nerve blocks in pain management, regional anesthesia, or botulinum injections.
Yes. With 128+ to 192+ element probes and over 60 imaging channels, Suresult ultrasound devices can assess muscle thickness, detect fasciculations, and identify changes in conditions like ALS, myopathies, or dystrophies.
Yes. Models with high-frequency linear probes are excellent for identifying superficial spinal landmarks and guiding minimally invasive or percutaneous spine procedures.
Most neurosurgeons find it intuitive. If you have basic POCUS training, you can begin scanning within hours. Built-in protocols and presets help you get comfortable quickly.
All Suresult devices have sealed surfaces, are compact, and are made with medical-grade materials. You can easily use probe covers or disinfect the device itself between patients. Please visit our 빠른 사용자 가이드, then click on "STEP 5: MAINTENANCE AND CARE." There, you can find our recommendations for cleaning and disinfection.