Critical care ultrasound machines, proven on real ICU scans
Ten unedited captures show what a handheld reads in critical care: B-lines, pericardial fluid, the caval window and the vessel a line goes into. Published pricing, software included, no subscription.
Quick answer
A critical care ultrasound machine is a bedside scanner that reads lung water, pump function, volume status and vessel anatomy without moving the patient.
- The D3 family carries phased, convex and linear heads in one probe: the heart, the caval window, the pleural line and the neck vessels on one device.
- Color Doppler, pulsed-wave Doppler and M-mode ship on every scanner on this page, and the L10SH and D3Ultra add Needle Enhance to the puncture guides.
- Stills and cine loops export from the app as DICOM, JPEG, PNG or MP4, so an ICU study reaches the record without a cart.
- The D3Pro and D3L scan for three hours continuously on a 4,200 mAh battery, which covers a full ward round.

The capture atlas
Ten real critical care windows, captured on Suresult handheld hardware
Unedited clinical captures · select any image to enlarge
3 windows3 windows

Diffuse B-lines in acute pulmonary edema on the D3Ultra
Vertical artifacts rise from the pleural line and run to the bottom of the sector, the pattern that separates cardiogenic edema from an obstructive cause of dyspnea. The case note describes an end-stage renal disease patient with orthopnea and hypoxia who improved after urgent dialysis.
8.3-second cine loop on a D3Ultra, submitted by the treating buyer with the case note
Pleural effusion with atelectasis
An anechoic collection sits above the diaphragm with collapsed lung floating inside it. This is the finding that a supine chest film misses most often, and it decides whether a drain goes in.
captured on a Suresult wireless probe in the shared clinical reference library; on-screen header reads 86 dB gain, 160 mm depth, harmonic 5.0 MHz
The pleural line, the reference for every lung window
A bright horizontal line with A-lines repeating below it is the normal aerated pattern. Gain and depth are set on this view before any anterior or posterior zone is scored.
captured on a Suresult wireless probe in the shared clinical reference library; on-screen header reads 83 dB gain, harmonic 5.0 MHz3 windows3 windows

Pericardial effusion on the D3Ultra
An anechoic rim surrounds the heart through the whole cardiac cycle. The buyer found it incidentally in a dialysis patient, and it is the ICU finding that most often changes management inside the hour.
6.7-second cine loop on a D3Ultra, submitted by the treating buyer with the case note
Apical four-chamber view on the PD1
All four chambers open from the apex on a dedicated phased-array head. This is the window for a visual estimate of ejection fraction and for comparing the two ventricles in shock.
6.9-second buyer clip on a PD1, submitted by Ana Lucia Telleria Torres
Parasternal long axis with M-mode on the CD2
The sector shows the left ventricle, the mitral and aortic valves and the left atrium, with an M-mode trace timing wall motion below it. One dual-head probe covered this and the abdominal window in the same session.
6.6-second buyer clip on a CD2 at 3.6 MHz, submitted by Felipe Jaramillo2 windows2 windows

Inferior vena cava on the D3Ultra
The caval lumen runs through the liver, labeled Vena Cava on screen by the scanning physician. Caval diameter and respiratory collapse read volume status before a fluid bolus is committed.
still frame on a D3Ultra at 3.2 MHz, dated 2025-10-19, from a German buyer's own case folder
Perihepatic free fluid
An anechoic collection sits in the perihepatic space, bordering the liver. The same convex window that measures the caval vein answers the free-fluid question on the way past.
captured on a Suresult wireless probe in the shared clinical reference library; on-screen header reads 80 dB gain, 200 mm depth, harmonic 5.0 MHz2 windows2 windows

Common carotid artery and internal jugular vein in long axis
The carotid artery and the internal jugular vein run across the field with parallel walls in long axis. This is the plane an in-plane needle follows, so the shaft and the tip stay in view during cannulation.
captured on a Suresult wireless probe in the shared clinical reference library; on-screen header reads 40 mm depth, 7.5 MHz
Moderate right hydronephrosis on the D3Ultra
The renal pelvis and calyces are dilated in the longitudinal plane. Obstruction is the reversible cause of acute kidney injury that a bedside scan finds before the creatinine trend explains itself.
still frame on a D3Ultra, dated 2026-06-19; the buyer's case note reports an obstructing stone confirmed afterwards
▶Select a card to switch capture
Technique basics
How the exam comes together, probe to report
Match the head to the ICU question.Cardiac windows sit between the ribs, so they need the phased sector. The convex head reaches the abdomen and the caval window, and the linear head images the pleural line and the neck vessels.
The convex and phased face on the D3Ultra
Start with the lung in respiratory failure.Set gain and depth on the pleural line first. Anterior zones separate A-lines from diffuse B-lines, and posterior zones find effusion and consolidation.
Pleural line at harmonic 5.0 MHz
Read the heart, then the caval window.The phased head shows pump function and pericardial fluid at 160 mm to start. The convex head then measures caval diameter and collapse before a fluid bolus is committed.
IVC at 3.2 MHz on the D3Ultra
Place the line on the linear head.In-plane and out-of-plane puncture guides draw the needle path over the vessel, and the flip and grid tools keep the orientation honest. Needle Enhance sharpens the shaft on the L10SH and the D3Ultra.
Puncture assist in the app
What the research says
The evidence, three studies checked
- Lung ultrasound outread the bedside chest film in ARDS.
In 32 patients with ARDS, lung ultrasonography was 93% accurate for pleural effusion and 97% for alveolar consolidation, against 47% and 75% for bedside chest radiography.
Lichtenstein et al., Anesthesiology 2004 - A bedside protocol changed the admitting diagnosis in one ICU patient in four.
In 125 consecutive ICU admissions scanned under a critical care ultrasonography protocol, findings modified the admitting diagnosis in 25.6% of patients and changed therapy in 17.6%.
Manno et al., Anesthesiology 2012 - Ultrasound guidance beat the landmark technique for internal jugular lines in the ICU.
Ultrasound-guided internal jugular cannulation succeeded in all 450 ICU patients, against 94.4% with the landmark technique, which punctured the carotid artery in 10.6%.
Karakitsos et al., Crit Care 2006
Pick your model
Pick the model that fits your day
One scanner for the whole ICU roundD3UltraThe D3Ultra carries phased, convex and linear heads in one probe, with 192 elements and 64 channels. Most of the atlas above came off this model, from lung B-lines to the caval window.
heads in one probe, one probe
$2,976 D3Ultra · Convex Linear Phased MultipuBuy nowD3Ultra 보기 →
Echo and central lines are the daily workCD2The CD2 pairs a 2.2/3.6 MHz phased head with a 7.5/10 MHz linear head in a 150 g body, across 192 elements and 64 channels. Cardiac windows to 190 mm and vascular access sit on the same probe.
150 g, phased + linear
$2,697 CD2 · Phased Linear Dual-Head UltrBuy nowView CD2 →
Long rounds without a chargerD3ProThe D3Pro scans for three hours continuously on a 4,200 mAh battery and carries the same three probe formats. Its convex and phased heads reach 305 mm.
three hours continuously, three formats
$2,697 D3Pro · Dual-Head 3-in-1 Wireless UlBuy nowView D3Pro →Scanner comparison
Seven Suresult handheld scanners for critical care, compared
Swipe to see all columns →
| 모델 | 가격 | 빈도 | 깊이 | 최상의 대상 |
|---|---|---|---|---|
D3Ultra | $2,976 | Phased 3.2/5.0 + convex 3.2/5.0 + linear 7.5/10 MHz | Phased and convex 90-300 mm, linear 20-100 mm | The full ICU exam on one 192-element probe, 64 channels, 2-hour battery |
D3Pro | $2,697 | Phased 3.2/5.0 + convex 3.2/5.0 + linear 7.5/10 MHz | Phased and convex 90-305 mm, linear 20-80 mm | Three formats with a 3-hour battery for long rounds, 192 elements |
CD2 | $2,697 | Phased 2.2/3.6 + linear 7.5/10 MHz | Phased 90-190 mm, linear 20-100 mm | Echo plus vascular access at 150 g, 192 elements and 64 channels |
L10SH | $3,534 | Linear 7.5/10 MHz | 20/40/60/100 mm | Line placement and lung windows, 256 elements with Needle Enhance |
D3L | $2,418 | Phased 3.2/5.0 + convex 3.2/5.0 + linear 7.5/10 MHz | Phased and convex 90-305 mm, linear 20-80 mm | Three formats with an 80-degree phased sector and a 3-hour battery |
D3 | $2,232 | Phased 3.2/5.0 + convex 3.2/5.0 + linear 7.5/10 MHz | Phased and convex 90-305 mm, linear 20-100 mm | The entry three-format handheld at 150 g, cable or Wi-Fi |
PD1 | $2,139 | Phased 2.5/2.8/3.6 MHz | 90-190 mm | A dedicated cardiac head, 128 elements and an 80-degree sector |
Against the known brands
Suresult vs Clarius PAL HD3, Butterfly iQ3 and GE Vscan Air SL for critical care
Swipe to see all columns →
| 결과 | 클라리우스 PAL HD3 | 버터플라이 iQ3 | GE 브이스캔 에어 SL | |
|---|---|---|---|---|
| ICU imaging | Phased, convex and linear heads in one probe on the D3 family. Phased depth 90-305 mm on the D3Pro, D3L and D3. 192 elements and 64 channels on the D3Ultra, 256 elements on the L10SH. | 1-15 MHz dual array, 307 g | 1-12 MHz single chip, 30 cm on the abdomen preset and 25 cm on cardiac presets, 300 g | Sector phased plus linear dual probe |
| Device price | $2,139 to $3,534, published on each product page | $5,395 published | $3,899 published | Starting at $4,999 published |
| 구독 | None. Software is included with the scanner. | Clarius Essentials is $695 a year, $1,785 for three years or $2,500 one time | Core is $299 a year, Advanced is $420 a year, or $1,500 once for five years of Advanced | Digital Tools for Vscan Air is sold as a separate software package from the scanner |
| Landed cost | Duties and shipping included in the checkout price, 1-7 day delivery | US list price; duties and shipping extra outside the US | US list price; duties and shipping extra outside the US | US list price; duties and shipping extra outside the US |
| Continuous scanning | 3 hours on the D3Pro and the D3L, on a 4,200 mAh battery, and 2 hours on the D3Ultra | Scan time about 60 minutes | Battery life up to 2 hours | 50 minutes of continuous scan time |
| Regulatory registrations | FDA 510(k) · ISO 13485 · EU MDR (CE) · TGA · ANVISA · Health Canada | FDA 510(k) | FDA 510(k) | FDA 510(k) |
- Ten critical care windows on this page are unedited captures from Suresult hardware, from lung B-lines to the internal jugular vein.
- Color Doppler, pulsed-wave Doppler, M-mode, measurements and DICOM export ship with every scanner on this page at no extra charge.
- There is no membership to renew.Clarius Essentials costs $695 a year and Butterfly Advanced costs $420 a year.
- The checkout price is the landed price: duties and shipping are included, with 1-7 day delivery.
- The D3 family carries phased, convex and linear heads in one probe, so the heart, caval window, lung and vessels stay on one device.
- The D3Pro and the D3L scan for three hours continuously on a 4,200 mAh battery, which covers a full ICU round on one charge.
- The L10SH carries a 256-element linear array with Needle Enhance for cannulation, at 150 g.
- Suresult scanners are registered under FDA 510(k), ISO 13485, EU MDR (CE) and Health Canada.
Clarius Essentials at $695 a year reaches $3,475 by year five, on top of the $5,395 PAL HD3. Butterfly's Advanced plan is $420 a year, which is $2,100 over the same five years, or $1,500 paid once. Suresult scanners carry no membership.
Three models, one decision
One conversation gets a direct recommendation: the right Suresult probe, or a straight “neither.”
Top Choice Handheld Ultrasound for Intensivists & Emergency Physicians
D3Ultra
D3초볼록 선형 위상 다목적 핸드헬드 초음파
빈도: 볼록형/위상 조절형 프로브 3.2/5.0MHz 선형 프로브 7.5/10MHz
스캔 깊이: 선형: 20~100mm, 볼록 및 위상 조절형: 90~300mm
중환자 치료
D3Pro
D3Pro Dual-Head 3-in-1 Wireless Ultrasound Scanner
빈도: 볼록형/위상 조절형 프로브 3.2/5.0MHz, 선형 프로브 7.5/10MHz
스캔 깊이: 볼록/위상 프로브: 90~305mm, 선형 프로브: 20~80mm
중환자 치료
CD2
컬러 도플러가 장착된 CD2 위상 선형 듀얼 헤드 초음파 192 소자
빈도: 위상 변조 프로브 2.2/3.6MHz, 선형 프로브 7.5/10MHz
스캔 깊이: 위상 프로브: 90~190mm, 선형 프로브: 20~100mm
중환자 치료
D3L
D3L 초음파 진단 프로브 128 소자, 볼록 선형 위상 3 모드
빈도: 볼록형/위상 조절형 프로브 3.2/5.0MHz 선형 프로브 7.5/10MHz
스캔 깊이: 볼록/위상 프로브: 90~305mm, 선형 프로브: 20~80mm
중환자 치료
D3
D3 듀얼 프로브 선형 볼록 위상 3 in 1 핸드헬드 초음파
빈도: Linear: 7.5/10 MHz, Convex & Phased 3.2/5 MHz
스캔 깊이: Linear: 20-100mm, Convex & Phased: 90-305mm
중환자 치료
B4D
B4D
빈도:
스캔 깊이:
C5SH
C5SH 64채널 고해상도 볼록 초음파 프로브 컬러 도플러
빈도: 3.2/5 MHz
스캔 깊이: 90-300mm
중환자 치료
C5SH-Pro
C5SH-Pro 64채널 고해상도 볼록형 초음파 프로브 컬러 도플러
빈도: 3.2/5 MHz
스캔 깊이: 90-300mm
중환자 치료
PD1
PD1 심장용 휴대용 휴대용 초음파 위상 프로브
빈도: 2.5/2.8/3.6 MHz
스캔 깊이: 90/130/160/190mm
중환자 치료
C5B
C5B 비용 효율적인 휴대용 흑백 초음파 볼록 프로브
빈도: 3.2/5 MHz
스캔 깊이: 90-305 mm
중환자 치료
What to Consider Before Buying a Handheld Ultrasound for Critical Care
Before you buy
구매 전 확인해야 할 사항
What is the best handheld ultrasound machine for critical care?
The Suresult D3Ultra fits most intensive care units, because it carries phased, convex and linear heads in one 192-element probe. The CD2 suits units where echocardiography and central lines are the daily work.
Which point-of-care ultrasound exams are standard in the ICU?
Lung ultrasound, focused echocardiography, inferior vena cava assessment, abdominal free-fluid scanning and ultrasound-guided vascular access are the five exams this page demonstrates. All five run on one handheld probe.
Can a handheld ultrasound replace a cart machine in the ICU?
A handheld answers the focused ICU questions: lung water, pump function, effusion, volume status and line placement. Comprehensive echocardiography, transesophageal imaging and full Doppler quantification stay on a cart system.
Is lung ultrasound more accurate than a bedside chest radiograph in ARDS?
A 2004 Anesthesiology study of 32 patients with ARDS found lung ultrasonography 93% accurate for pleural effusion, against 47% for bedside chest radiography.
How often does a bedside ultrasound change the ICU diagnosis?
In 125 consecutive ICU admissions scanned under a critical care ultrasonography protocol, findings modified the admitting diagnosis in 25.6% of patients and changed medical therapy in 17.6%.
Does ultrasound guidance reduce central line complications?
A randomized study of 900 critical care patients found carotid artery puncture in 10.6% of landmark internal jugular attempts, significantly more than in the ultrasound-guided group.
How much does a critical care ultrasound machine cost?
A Suresult handheld for critical care runs from $2,139 to $3,534 with software included. The Clarius PAL HD3, Butterfly iQ3 and GE Vscan Air SL publish $3,899 to $5,395 before any membership fee.
Which model covers the whole shock assessment?
The D3Ultra and the D3Pro carry phased, convex and linear heads in one probe. That covers the cardiac, caval, abdominal and lung windows of a shock assessment.
What imaging depth do adult ICU cardiac windows need?
Suresult phased heads reach 190 mm on the CD2 and the PD1, 300 mm on the D3Ultra and 305 mm on the D3Pro, D3L and D3. Every one of those ranges covers adult apical and subcostal windows.
Is there a subscription fee on a Suresult scanner?
Suresult scanners carry no subscription. Clarius Essentials is $695 a year, and Butterfly's Advanced plan is $420 a year or $1,500 once for five years.
Can an ICU study go into the patient record?
The seven models on this page save stills and cine loops of 100 to 1,000 frames in the app, and export them as DICOM, JPEG, PNG or MP4.
How long does the battery last on an ICU round?
The D3Pro and the D3L scan for three hours continuously on a 4,200 mAh battery. The D3Ultra runs two hours, and the CD2 and L10SH run 90 minutes.
Does the same probe do lung imaging and line placement?
The linear head images both the pleural line and the neck vessels. On the L10SH that head is a 256-element array with Needle Enhance for cannulation.
How is a handheld probe cleaned between ICU patients?
The probe is wiped after each use with a soft cloth dampened with isopropyl alcohol, for one minute or until it is visibly clean. For wipe disinfection the user manual lists T-spray II, a quaternary ammonium agent, at under 10 minutes of contact time.
Which Suresult model is the cheapest way into ICU echocardiography?
The PD1 is the entry phased-array model, with 128 elements, 2.5/2.8/3.6 MHz and 90 to 190 mm of depth, at $2,139.
Does a handheld work for mechanically ventilated patients?
A 2004 Anesthesiology study of 32 patients with ARDS found lung ultrasonography 97% accurate for alveolar consolidation, against 75% for bedside chest radiography. Lung ultrasonography also quantified the extent of lung injury, which chest radiography could not.
자유 소프트웨어,
무제한 스캔
Suresult의 휴대용 초음파 기기에는 추가 비용 없이 무제한 기능을 제공하는 강력한 소프트웨어가 탑재되어 있습니다. iOS, Android, Windows에서 무료 DICOM 및 펄스 도플러 기능을 이용할 수 있을 뿐만 아니라 사용자 친화적인 인터페이스까지 제공되므로, 소프트웨어 비용 부담 없이 최고 수준의 진료에 전념할 수 있습니다.
모든 디테일을 포착하고, 정밀하게 안내하며, 손쉽게 공유하세요
당사의 올인원 솔루션으로 초음파 검사 워크플로우를 개선하세요. 매번의 검사에서 정밀함, 간편함, 효율성을 직접 경험해 보세요.
17개 이상의 특수 프리셋
볼록 / 위상 조절 프로브
선형 프로브
정밀한 진단을 위한 27가지 자동 측정법
신속하고 실시간 평가를 위한 완벽한 도구 세트로 업무를 간소화하세요.
B-모드
- 길이, 면적/둘레, 각도, 선분, 거리
- Depth and angle readouts for needle and injection guidance
- Obstetric biometrics (gestational age, EFW) when your caseload needs them
B+M 모드
- 심박수, 시간, 거리
- 좌심실 내경 (LVIDd, LVIDs)
- 박출 분율(EF), 박출량(SV)
B+PW 모드
- 속도, 심박수, S/D 비율, 수심
- 선박 유량 자동 측정
- 최대 수축기 속도(PS), 이완기 말기 속도(ED)
- 시간 평균 최대 속도(TAMAX), 시간 평균 평균 속도(TAMEAN)
- 맥동 지수(PI), 저항 지수(RI)
- 선박 직경 (DIAM), 유량 (FL)
시네 루프
최대 1000 프레임 (≈165초) 미묘한 디테일 하나하나까지 포착하기 위한 연속적인 움직임.
펑크 지원 기능
정밀함을 만끽하세요 면 내 그리고 면외 가이드 중재 과정에서 자신감을 높이기 위해.
유연한 파일 내보내기
스캔한 파일을 손쉽게 저장하고 공유하세요. JPEG, MP4, PNG 또는 DICOM 다양한 형식을 지원하며, 사용자의 워크플로우와 원활하게 연동됩니다.

Expert Guidance
Talk to a Scanner Specialist
Tell Suresult about your daily workflow and get a personal scanner recommendation with an all-inclusive quote.
- Free scanner-fit consultation — probes, frequency and depth matched to your procedures
- All-inclusive quote — shipping, customs clearance and applicable taxes covered
- Fast delivery — ships within 24 hours, 1–7 days door to door
- No required software subscription — iOS, Android and Windows apps included
- 30-day returns and 24/7 support
Live chat opens right here — no forms, no waiting.
자주 묻는 질문
Yes. With a full range of probes and excellent resolution, as in Suresult devices, handheld ultrasound can perform the FAST, lung, and vascular scans needed in trauma care. Sometimes, they even outperform full-size systems by cutting out setup delays.
Minimal. If you've used ultrasound before, Suresult’s interface will feel familiar, with recognizable icons and measurement tools. For clinicians new to ultrasound, basic point-of-care ultrasound (POCUS) training is usually enough to get started confidently.
Absolutely. All Suresult devices with a phased probe support focused cardiac views and provide automated measurements like heart rate, stroke volume, ejection fraction, IVC collapsibility, and more.
Suresult ultrasound devices offer 1.5–3 hours of active scanning time on a full charge. Many models also support wireless charging, so you can top up the battery between scans with minimal downtime.
Yes, they’re extremely valuable in managing ventilated patients. You can use them to monitor aeration, detect B-lines, pleural effusions, pneumothorax, and guide weaning by assessing diaphragmatic movement.




