Neonatal ultrasound probes, chosen by what a newborn unit actually scans

Two unedited infant captures show what a handheld reads on a small patient, from a Graf-method hip plane to an infant tendon set beside an adult’s. Published pricing, software included, no subscription.

Every clinical scan on this page is an unedited capture from Suresult handheld hardware ·Trusted by 8,717 clinicians →

Risposta rapida

A neonatal ultrasound probe is a small-faced handheld scanner running 5 to 14 MHz, used to image a newborn's lung and hip at the incubator.

  • The D2LM carries a 10/12 MHz linear head and a 5/7 MHz micro-convex head with an R20, 88 degree face in one 237 g body.
  • The E11 weighs 103 g, images from 30 to 80 mm on an R13 micro-convex head, and scans for three hours on one charge.
  • Color Doppler, pulsed-wave Doppler, M-mode and power Doppler ship on every scanner on this page, with no membership to unlock them.
  • Stills and cine loops export from the app as DICOM, JPEG, PNG or MP4, so a cot-side study reaches the chart without a cart.
Suresult D2LM handheld ultrasound

The capture atlas

A real infant scan, captured on Suresult handheld hardware

Unedited clinical captures · select any image to enlarge

Infant hip1 window

Infant hip, Graf method

Infant hip, Graf method

A developmental hip dysplasia sweep on an infant, with the on-screen calipers set for the alpha angle. The small footprint reaches the joint without displacing the leg.

recorded on a Suresult handheld during a developmental hip screen
Anterior hip joint, live sweepUltrasound key frame

Select a card to switch capture

Technique basics

How the exam comes together, probe to report

  1. Match the head to the patient, not to the room.Match the head to the patient, not to the room.

    A newborn chest wall, hip, abdomen or vessel sits within about 8 cm of the skin. A high-frequency linear head and a small micro-convex head cover most of that work. The D2LM carries both faces in one body.

    Linear 10/12 MHz, micro-convex 5/7 MHz
  2. Use the micro-convex face where a flat head will not sit.Use the micro-convex face where a flat head will not sit.

    The E11 presents an R13 micro-convex face on a 103 g body and images from 30 to 80 mm. That geometry gets between small ribs and under a costal margin.

    R13 face, 103 g, 3-hour battery
  3. Keep depth shallow and let the linear head carry the detail.Keep depth shallow and let the linear head carry the detail.

    The L14 runs 10/14 MHz across a 25 mm face with 192 elements and images from 20 to 80 mm. On-screen puncture guides put a target position and radius over the live image.

    20 to 80 mm, 192 elements
  4. Save the study before you leave the cot.Save the study before you leave the cot.

    Every scanner on this page writes stills and cine loops to the tablet and exports DICOM, JPEG, PNG or MP4. Storage is local and no membership gates it.

    DICOM export, no membership

What the research says

The evidence, three studies checked

  • A lung ultrasound score predicted which preterm babies needed surfactant.

    In 130 neonates on continuous positive airway pressure, the lung ultrasonography score predicted surfactant need with an area under the curve of 0.93 below 34 weeks' gestation.

    Brat et al., JAMA Pediatr 2015
  • Lung ultrasound found every pneumothorax in decompensating newborns.

    Among 42 infants who suddenly decompensated, lung ultrasound diagnosed pneumothorax with 100% sensitivity and 100% specificity, against 84% and 56% for clinical evaluation.

    Raimondi et al., J Pediatr 2016
  • Ultrasound guidance cut umbilical catheter tip malposition in a randomized trial.

    In 53 randomized neonates, tip malposition occurred in 42.3% of ultrasound-guided umbilical venous catheters against 74% with the standard insertion method.

    Kaur et al., Indian J Pediatr 2022

Pick your model

Pick the model that fits your day

MOST CHOSENSuresult D2LMA newborn unit buying one scannerD2LM

The D2LM puts a 10/12 MHz linear face and a 5/7 MHz micro-convex face on one 237 g body. That pairing covers the chest wall, the hip, the abdomen and a line site without swapping hardware.

two faces, one body, dual head

$2,418 D2LM · Handheld Ultrasound - Micro-Buy nowView D2LM →
Suresult E11The smallest patients, the tightest windowsE11

The E11 is the lightest scanner here at 103 g, with an R13 micro-convex face and 30 to 80 mm of depth. Its battery runs three hours of continuous scanning between charges.

103 g, R13 face, micro-convex

$1,767 E11 · Micro-Convex Portable UltrasBuy nowView E11 →
Suresult D3UltraA unit that also scans adultsD3Ultra

The D3Ultra carries convex, linear and phased formats on 192 elements and 64 channels, reaching 300 mm on the convex and phased faces. It is the handheld behind the infant hip capture in the atlas.

three formats, three heads

$2,976 D3Ultra · Convex Linear Phased MultipuBuy nowVisualizza D3Ultra →

Scanner comparison

Seven Suresult handhelds a neonatal unit can actually use, compared

Swipe to see all columns →

ModelloPrezzoFrequenzaProfonditàIl meglio per
Suresult D2LMD2LM$2,418Linear 10/12 MHz, micro-convex 5/7 MHzLinear 20 to 80 mm, micro-convex 60 to 160 mmTwo faces for a newborn: superficial linear plus an R20, 88 degree micro-convex
Suresult E11E11$1,767Micro-convex 8/11 MHz30 to 80 mmThe smallest face here at R13, on the lightest body at 103 g
Suresult L14L14$2,139Linear 10/14 MHz20 to 80 mm192 elements on a 25 mm face, for chest wall, hip and line work
Suresult L10SHL10SH$3,534Linear 7.5/10 MHz20 to 100 mm256 elements and 64 channels, with Needle Enhance on the puncture guides
Suresult D3UltraD3Ultra$2,976Convex 3.2/5.0, linear 7.5/10, phased 3.2/5.0 MHzConvex and phased 90 to 300 mm, linear 20 to 100 mmThree formats on 192 elements when the same probe also scans adults
Suresult D3LD3L$2,418Convex 3.2/5.0, linear 7.5/10, phased 3.2/5.0 MHzConvex and phased 90 to 305 mm, linear 20 to 80 mmThree formats with a 4,200 mAh battery and 3 hours of scanning
Suresult CD2CD2$2,697Linear 7.5/10 MHz, phased 2.2/3.6 MHzLinear 20 to 100 mm, phased 90 to 190 mmA sector face for the heart and a linear face for lines, at 150 g

Against the known brands

Suresult vs Clarius L15 HD3, Butterfly iQ3 and GE Vscan Air CL for neonatology

Swipe to see all columns →

RisultatoClarius L15 HD3Farfalla iQ3GE Vscan Air CL
Probe formatsMicro-convex, linear, convex and phased faces across the range; the D2LM and E11 are the micro-convex optionsA linear scanner, published at 5 to 15 MHz with 7 cm of depthOne semiconductor probe; no micro-convex head offeredA curved and a linear array; no micro-convex head offered
Micro-convex newborn headYes: the E11 at R13 and the D2LM at R20, 88 degreesNot offered in the L15 HD3Not offeredNot offered
Device price$2,418 for the D2LM and $1,767 for the E11, published on the product pages$3,795 for the scanner$3,899 for the probeDa $4.999
Costo del softwareNone. The app, its measurements and DICOM export ship with the scanner$695 a year for Essentials, or $2,500 once, or $1,785 for three years$299 a year for Core, $420 a year for Advanced, or $1,500 once for five yearsDigital Tools sold separately as a 1-year or 3-year subscription; public estimates put it at $300 to $600 a year
Software cost over five years$0$3,475 at $695 a year$1,495 at $299 a year, or $1,500 paid once$1,500 to $3,000 on those public estimates
PiattaformeiOS, Android and Windows on every model on this pageiOS e AndroidiOS e AndroidiOS e Android
Landed costDuties and shipping included in the checkout price, delivered in 1 to 7 daysUS list price; duties and shipping extra outside the USUS list price; duties and shipping extra outside the USUS list price; duties and shipping extra outside the US
Regulatory registrationsFDA 510(k) · ISO 13485 · EU MDR (CE) · TGA · ANVISA · Health CanadaFDA 510(k)FDA 510(k)FDA 510(k)
Where Suresult wins
  • Two faces in one body: the D2LM pairs a 5/7 MHz micro-convex head with a 10/12 MHz linear head.
  • A micro-convex head that fits a newborn: the E11 presents an R13 face on a 103 g scanner.
  • No software fee.Color Doppler, M-mode, measurements and DICOM export ship with every scanner on this page.
  • Puncture guides on every model on this page, with Needle Enhance added on the L10SH and the D3Ultra.
  • iOS, Android and Windows on every model on this page, so the app runs on the tablet already at the cot side.
  • The checkout price is the landed price, with duties and shipping included and delivery in 1 to 7 days.
  • Real infant footage on this page, including a Graf-method hip plane captured on a Suresult handheld.
  • Documentation published for FDA 510(k), ISO 13485, EU MDR (CE), TGA, ANVISA and Health Canada.
The five-year math

Clarius publishes $695 a year for its Essentials membership, which reaches $3,475 by year five before the scanner itself is counted. Butterfly publishes $299 a year for Core, or $1,500 once for five years. Suresult scanners carry no membership.

D2LM, paid once$2,418Clarius L15 HD3: scanner + membership$695$695$695$695$695= $3,475 in fees alone by year five

Three models, one decision

Not sure which model fits your cases?

One conversation gets a direct recommendation: the right Suresult probe, or a straight “neither.”

I migliori ultrasuoni palmari per la migliore diagnostica per immagini neonatale point-of-care

Si concentra sulla diagnosi precoce, su interventi più rapidi e su minori disagi per i neonati vulnerabili.
ultrasuoni palmari multiuso d3ultra convesso lineare fasato
D3Ultra

Ultrasuoni palmari multifunzionali lineari sfasati convessi D3Ultra

Frequenza: Sonda convessa / fasata 3.2/5.0MHz Sonda lineare 7.5/10MHz

Profondità di scansione: Lineare: 20-100 mm, convesso e sfasato: 90-300 mm

Neonatologia

Il phased array (90-300 mm) gestisce l'imaging cardiaco e cranico neonatale, mentre la sonda convessa (90-300 mm) copre le esigenze addominali. Il Doppler PW e l'M-Mode aggiungono approfondimenti funzionali, ottimi per i pazienti fragili in cui la portabilità è importante.
buy scanner
d3pro 192 elementi lineari convessi fasati 3 in 1 ecografi doppler a colori wireless
D3Pro

D3Pro Dual-Head 3-in-1 Wireless Ultrasound Scanner

Frequenza: Sonda convessa / fasata 3.2/5.0MHz, sonda lineare 7.5/10MHz

Profondità di scansione: Sonda convessa / fasata: 90-305 mm, Sonda lineare: 20-80 mm

Neonatologia

The phased head (90-305 mm) covers neonatal cardiac and cranial windows and the convex head the abdomen, with PW Doppler and M-mode for function. At 257 g with a 3-hour battery it works through a shift at the cot side.
buy scanner
sonda diagnostica a ultrasuoni d3l 128 elementi, convessa lineare fasata a 3 modalità
D3L

Sonda diagnostica a ultrasuoni D3L 128 elementi, lineare convessa fasata 3 modalità

Frequenza: Sonda convessa / fasata 3.2/5.0MHz Sonda lineare 7.5/10MHz

Profondità di scansione: Sonda convessa / fasata: 90-305 mm, Sonda lineare: 20-80 mm

Neonatologia

La sonda fasata (90-305 mm, 80°) per la funzione cardiaca/craniale neonatale, convessa (70°) per il Doppler addominale-PW e M-Mode aggiunge la funzione. Senza fili e delicato, con i suoi 237 grammi, è una vittoria per i neonati.
buy scanner

Cosa considerare prima di acquistare un ecografo portatile per neonati

Scelga il dispositivo ideale per i neonati pretermine e in assistenza critica, con sonda ad alta frequenza e diagnostica ad accesso rapido.

Before you buy

Cosa controllare prima dell'acquisto

What is the best portable ultrasound for a NICU?

The Suresult D2LM is the only Suresult handheld carrying both a 5/7 MHz micro-convex head and a 10/12 MHz linear head in one body. Units that need the smallest face choose the E11 instead.

Which probe format do you need for neonatal ultrasound?

A newborn exam needs two formats. A 10 to 14 MHz linear head reads the chest wall, hip and vessels. A micro-convex head running 5 to 11 MHz reaches windows a flat head cannot sit on.

What is a micro-convex probe, and why does it matter for newborns?

A micro-convex probe has a small curved face, quoted as a radius. The Suresult E11 uses R13 and the D2LM uses R20, which is what lets either sit between small ribs.

Can a handheld ultrasound image a newborn's lung?

Yes. The pleural line and the vertical artifacts below it are superficial findings, well inside the 20 to 80 mm range of the Suresult L14 linear head.

Does lung ultrasound predict the need for surfactant?

A 2015 study of 130 neonates on CPAP found a lung ultrasonography score predicted surfactant need with an area under the curve of 0.93 below 34 weeks' gestation.

Can a handheld find a pneumothorax in a decompensating newborn?

In a 2016 study of 42 suddenly decompensating infants, lung ultrasound identified pneumothorax with 100% sensitivity and 100% specificity, against 84% and 56% for clinical evaluation.

Does ultrasound help place an umbilical venous catheter?

A 2022 randomized trial of 53 neonates found tip malposition in 42.3% of ultrasound-guided umbilical venous catheters, against 74% with the standard insertion method.

What frequency should a neonatal probe run at?

Superficial newborn work sits at 10 MHz and above, which is why the L14 runs 10/14 MHz and the D2LM linear head runs 10/12 MHz. Deeper windows drop to 5 to 8 MHz.

How much does a neonatal ultrasound probe cost?

The Suresult E11 is $1,767 and the D2LM is $2,418, software included. Clarius publishes $3,795 for the L15 HD3 and Butterfly publishes $3,899 for the iQ3.

Is there a subscription on a Suresult scanner?

No. Color Doppler, M-mode, measurements, puncture guides and DICOM export are included with the scanner. Clarius publishes $695 a year for Essentials and Butterfly publishes $299 a year for Core.

Does the app export DICOM?

Yes. Every scanner on this page saves stills and cine loops to the tablet. The app exports DICOM, JPEG, PNG or MP4 to local storage, with no membership required.

Can the same probe scan an infant hip?

Yes. The atlas on this page shows a Graf-method coronal hip plane captured on a Suresult D3 handheld at 60 mm depth with a 10 MHz harmonic linear head.

Can a handheld replace the cart scanner in a newborn unit?

No. A handheld covers focused questions: lung pattern, hip screening, line position and gross cardiac assessment. Detailed cranial studies and full quantitative echocardiography stay on a cart system.

Which Suresult model suits a neonatal unit, a mixed pediatric clinic or a general ward?

A neonatal unit buying one scanner takes the D2LM. The smallest windows take the E11. A unit that scans adults as well takes the D3Ultra or the D3L.

Software gratuito,
Scansioni illimitate

Gli ultrasuoni portatili Suresult sono dotati di un potente software che le offre funzioni illimitate senza costi aggiuntivi. Può usufruire gratuitamente di DICOM e doppler a onde pulsate, oltre a un'interfaccia facile da usare su iOS, Android e Windows, in modo da potersi concentrare sull'erogazione di cure di alta qualità senza dover pagare alcun software.

Suresult App ecografica gratuita per Apple Android Windows

Compatibile con tutte le piattaforme, a vita Aggiornamenti gratuiti

Cattura ogni dettaglio, guida con precisione e condivide con facilità.

Migliori il suo flusso di lavoro ecografico con la nostra soluzione all-in-one. Sperimenti precisione, semplicità ed efficienza in ogni scansione.

17+ Preset specializzati

Sonda convessa / fasata

AddomeGinecologiaOstetricaCardiacoUrologiaRenePolmone

Sonda lineare

TiroideLa pellePiccole partiPediatriaVascolareCarotideSenoMSKNervoFlusso del vaso

5 modalità di scansione

27 Misurazioni automatizzate per una diagnostica precisa

Semplifica il suo lavoro con un set completo di strumenti per valutazioni rapide e in tempo reale.

Modalità B

  • Lunghezza, area/circonferenza, angolo, traccia, distanza
  • Depth and angle readouts for needle and injection guidance
  • Obstetric biometrics (gestational age, EFW) when your caseload needs them

Modalità B+M

  • Frequenza cardiaca, tempo, distanza
  • Diametro interno del ventricolo sinistro (LVIDd, LVIDs)
  • Frazione di eiezione (EF), volume della corsa (SV)

Modalità B+PW

  • Velocità, frequenza cardiaca, rapporto S/D, profondità
  • Misurazione automatica del flusso del serbatoio
  • Velocità sistolica di picco (PS), Velocità diastolica finale (ED)
  • Velocità massima mediata nel tempo (TAMAX), Velocità media mediata nel tempo (TAMEAN)
  • Indice di pulsatilità (PI), Indice resistivo (RI)
  • Diametro del vaso (DIAM), flusso (FL)

Loop Cine

Registra fino a 1000 fotogrammi (≈165 secondi) di movimento continuo per catturare ogni minimo dettaglio.

Funzione di assistenza alla perforazione

siringa

Godetevi la precisione in piano e guide fuori piano per aumentare la sua fiducia durante gli interventi.

Esportazioni di file flessibili

Salvi e condivida le sue scansioni senza sforzo in JPEG, MP4, PNG o DICOM formati, integrandosi perfettamente con il suo flusso di lavoro.

Suresult specialist guiding an ultrasound-led procedure

Expert Guidance

Talk to a Scanner Specialist

Tell Suresult about your daily workflow and get a personal scanner recommendation with an all-inclusive quote.

  • Free scanner-fit consultation — probes, frequency and depth matched to your procedures
  • All-inclusive quote — shipping, customs clearance and applicable taxes covered
  • Fast delivery — ships within 24 hours, 1–7 days door to door
  • No required software subscription — iOS, Android and Windows apps included
  • 30-day returns and 24/7 support
Talk to an Expert

Live chat opens right here — no forms, no waiting.

FAQ