The right scanner runs the highest frequency that still reaches the clinic’s deepest recurring target, then completes the full Doppler, archive and ownership-cost workflow.
Suresult prices update live from the Suresult store; Clarius prices and plans checked October 30, 2026. This guide compares diagnostic high-frequency ultrasound machines for aesthetics and superficial imaging.
Different categoryA diagnostic scanner receives echoes to form real-time B-mode and Doppler images. HIFU concentrates acoustic energy at a focal zone as treatment. One word, two purchases: the scanner images the tissue, and HIFU treats it.
What MHz Do Fillers and Facial Arteries Need?
For fillers and facial arteries, use 18–24 MHz at the forehead, glabella, nose and lips, where the arteries sit 2.52 to 5.6 mm deep, and 16–20 MHz along the facial artery, 6.27 to 8.04 mm deep. A 2025 Delphi consensus recommends a 15 MHz linear probe as the minimum. Suresult’s L24Pro (18/24 MHz) serves the shallow band and the L20Pro (16/20 MHz) the facial artery, cheek and jawline.
| Target | Depth | Band for this depth | Suresult handheld |
|---|---|---|---|
| Skin layers and superficial fillerEpidermis, dermis, upper subcutis | First 10 mmMlosek 2021: 20 MHz reaches about 10 mm | 20–24 MHz | L24Pro or L2418/24 MHz, 10–25 mm |
| Dorsal nasal arteryNasion | 2.52 mm left (median), 2.66 mm right (mean)Ortiz Middleton 2025, 50 women | 18–24 MHz | L24Pro or L2418/24 MHz, 10–25 mm |
| Superficial temporal artery, frontal branchMiddle forehead, lateral canthal line | 2.7 mmPhumyoo 2020, 19 cadavers and 14 volunteers | 18–24 MHz | L24Pro or L2418/24 MHz, 10–25 mm |
| Supratrochlear arteryGlabella at rest | 3.34 mm (SD 0.6)Cotofana 2020a, 41 volunteers | 18–24 MHz | L24Pro or L2418/24 MHz, 10–25 mm |
| Supraorbital arteryGlabella at rest | 3.54 mm (SD 0.8)Cotofana 2020a, 41 volunteers | 18–24 MHz | L24Pro or L2418/24 MHz, 10–25 mm |
| Angular arteryBeside the nose, deep pyriform space | 3.6 mm (SD 1.7)Franceschelli 2024, 332 hemifaces | 18–24 MHz | L24Pro or L2418/24 MHz, 10–25 mm |
| Inferior labial arteryLower lip | 5.2 mmCotofana 2020b, 41 volunteers | 18–24 MHz | L24Pro or L2418/24 MHz, 10–25 mm |
| Superior labial arteryUpper lip | 5.6 mmCotofana 2020b, 41 volunteers | 18–24 MHz | L24Pro or L2418/24 MHz, 10–25 mm |
| Facial arteryFrom the mandibular border up to the lateral nasal ala | 6.27 mm to 8.04 mmPourani 2025, 10 Doppler studies | 16–20 MHz | L20Pro or L2016/20 MHz, 10–40 mm |
Band basis: Mlosek 2021 favors 20–30 MHz once a scan includes the dermis and subcutaneous tissue; Vasconcelos-Berg 2024 images the infraorbital artery at 18 MHz and the nose and tear trough at 20 MHz; Jaguś 2021 states that 18–22 MHz shows vessels about 0.1 mm across.
A frequency-first purchase decision
Buying for dermatology? The dermatology page compares the Suresult models for that work window by window, with real captures, verified specs and live pricing. See the dermatology page →
Choose the working window, then prove the workflow.
The 15, 20 and 24 MHz labels narrow the field. A same-target demonstration, complete Doppler stack, archive path, platform compatibility and five-year cost decide the purchase.
What we evaluated: As independent equipment evaluators with deep ultrasound knowledge, our frequency-led scope covered Suresult L24Pro, Suresult L20, Clarius L20 HD3 and Clarius L15 HD3 under the same published buyer criteria.
Quick Answer
For shallow, face-first diagnostic imaging, we choose the Suresult L24Pro as the premium specialist; the Suresult L20 is the value route at $3,000, with the 16/20 MHz band and depth settings to 40 mm.
Clarius L20 HD3 is the premium software and education ecosystem route. Clarius L15 HD3 changes the answer when broader anatomy, a wider field of view or targets beyond 4 cm matter more than the 20–24 MHz specialist lane.
For high frequency ultrasound for aesthetics, we choose by the live image at the deepest target the clinic must see. The demo-day acceptance test runs Color, Power and PW Doppler, the archive and export path, platform compatibility, heat, battery and support on that same target.
The shortest rule: choose the highest usable frequency that still reaches the deepest recurring target, then make the exact quoted system pass a same-target demonstration.
Four current purchase routes
High-Frequency Ultrasound Machines Compared
Ranked for clinics whose main work is diagnostic imaging of the superficial face. The first columns carry the fields that decide fit.
Clarius Oct 30, 2026 · Suresult live · USD| System | Frequency / depth | Diagnostic workflow | Current price / subscription | Best for / our verdict |
|---|---|---|---|---|
Suresult L24ProPosition 1 · face-first premium | 18/24 MHz 10, 15, 20 or 25 mm | B, M, Color, Power, PW, Needle Enhance; iOS, Android, Windows; local files and DICOM | $4,185 Free lifetime software | Preferred specialist for recurring shallow facial work. Deeper facial planes to 40 mm: L20Pro. |
Suresult L20Position 2 · best value | 16/20 MHz 10, 20, 30 or 40 mm | B, M, Color, Power, PW, Needle Enhance; iOS, Android, Windows; local files and DICOM | $3,000 Free lifetime software | Best value with more depth reserve. 24 MHz facial work: L24Pro or L24. |
Clarius L20 HD3Position 3 · ecosystem route | 8–20 MHz Up to 4 cm | B, M, Color, Power; PW, Needle Enhance, local/cloud storage and DICOM with Essentials; iOS 16+ and Android 13+ | $5,395 Essentials $695/year | Premium software and education ecosystem. Essentials adds PW Doppler, Needle Enhance and DICOM. |
Clarius L15 HD3Position 4 · broader depth | 5–15 MHz Up to 7 cm | B, M, Color, Power; PW, Needle Enhance, local/cloud storage and DICOM with Essentials; iOS 16+ and Android 13+ | $3,795 Essentials $695/year | Broader-depth face-and-body route. 50 mm field of view for larger areas. |
Clarius Essentials also comes at $1,785 for three years or $2,500 once (Clarius US store, October 30, 2026).
Which Frequency Route Fits Your Clinic?
Choose an ultrasound machine for facial aesthetics by the deepest structure the clinic needs to see. That one depth sets the frequency lane, and the lane sets the model.
Quick List: Our Four Current Picks
We ordered the systems for a dedicated high-frequency aesthetic and superficial-imaging buyer. We used the same five criteria for every model.
- Suresult L24ProBest face-first specialist fit in this set: 18/24 MHz across 10–25 mm, with the L20Pro for planes to 40 mm.
- Suresult L20Strongest price-to-workflow value: B, M, Color, Power and PW Doppler with depth settings to 40 mm.
- Clarius L20 HD3Strong premium ecosystem alternative: 8–20 MHz to 4 cm, with Clarius aesthetics software in Essentials.
- Clarius L15 HD3Correct conditional choice for broader and deeper work: 5–15 MHz to 7 cm across a 50 mm field.
Four High-Frequency Ultrasound Systems Reviewed
Each system is judged on the five criteria above and ends with the work it leads and the model that fits the rest.
01 · Preferred face-first premium choice
01Suresult L24Pro
Our verdict: the most task-specific route here for clinics that repeatedly image shallow facial targets inside the 10–25 mm lane.
The L24Pro runs two settings, 18 and 24 MHz, with selectable depths of 10, 15, 20 and 25 mm. It carries 256 elements and 64 channels, runs B, M, Color, Power and PW Doppler with Needle Enhance, and scans for up to 4 hours per charge. It works on iOS, Android and Windows, saves local files and DICOM, and is FDA 510(k)-cleared under K211321, IP67-rated and drop-tested.
The buyer case is specialization. When the practice’s daily questions stay close to the surface, a shallow working window keeps the purchase focused. The L24Pro’s $4,185 checkout price is also its five-year hardware-plus-software total, because the imaging software and its updates are free for the life of the probe.
The deciding test is a live image at the clinic’s deepest recurring target, followed by the Color, Power and PW Doppler, save, export and reopen loop. The L20 vs L24 aesthetic ultrasound comparison puts the two Suresult bands side by side.
02 · Best value and depth reserve
02Suresult L20
Our verdict: the value first buy when the clinic wants a 20 MHz superficial route and depth settings to 40 mm, with a five-year total equal to its $3,000 price.
The L20 offers 16 and 20 MHz settings with depths of 10, 20, 30 and 40 mm. It carries 192 elements and 64 channels, runs B, M, Color, Power and PW Doppler with Needle Enhance, and works on iOS, Android and Windows with local files and DICOM. Depth to 40 mm makes it the first purchase when the practice needs depth reserve. On the L20, FaceAtlas AI starts at $50 a month.
At $3,000 with lifetime free software, the L20’s hardware price is also its five-year total. The demo-day test sets that price beside the full workflow: slow-flow Doppler, contact on facial curves, connection stability, export, heat and the actual display device.
The L20 ships with duties-paid delivery, a 2-year warranty and a 30-day trial, and like the L24Pro it is FDA 510(k)-cleared under K211321, IP67-rated and drop-tested. When a 25 mm face-first specialist and a 40 mm value route both fit, run the same target and record loop on both before choosing.
03 · Premium ecosystem alternative
03Clarius L20 HD3
Our verdict: choose this route when the clinic wants the polished Clarius aesthetics, education, storage and DICOM ecosystem.
Clarius L20 HD3 publishes an 8–20 MHz range, depth up to 4 cm and a 25 mm field of view. The current U.S. store lists B, M, Color and Power Doppler, while PW Doppler, local/cloud storage and DICOM appear with Essentials. The current compatibility floor is iOS 16+ and Android 13+. That is a coherent specialist workflow, especially for buyers who already value the Clarius platform.
On October 30, 2026 the Clarius US store priced the scanner at $5,395 and Essentials at $695 for one year, $1,785 for three years or $2,500 as a one-time license. Five annual payments bring the five-year total to $8,870; the one-time route brings it to $7,895.
Clarius gives the scanner about 60 minutes of scanning per charge and a recommended maximum exam time of 20 minutes, so the demo runs B-mode and Doppler through a full clinic session while watching heat, frame rate, connection recovery and battery. The scanner comes with product support and 30-day returns, and Essentials adds on-demand education (Clarius US store, October 30, 2026). The broader ultrasound for med spas buyer guide handles ecosystem and procedure-mix routing across more systems.
04 · When broader depth changes the answer
04Clarius L15 HD3
Our verdict: the correct conditional route when broader face-and-body work and targets beyond the specialist 4 cm lane matter more than the highest superficial frequency.
Clarius L15 HD3 publishes a 5–15 MHz band, depth up to 7 cm and a 50 mm field of view. It reaches the 15 MHz minimum recommended in the 2025 modified Delphi consensus for learning and routine diagnostic ultrasound in cosmetic filler practice. Doppler, archive and live-image evaluation decide the rest of the purchase.
On October 30, 2026 the Clarius US store priced the L15 HD3 at $3,795, with the same Essentials options. Five annual payments of $695 bring the total to $7,270; the $2,500 one-time license brings it to $6,295. The wider field and deeper reach make it a different purchase from a 20–24 MHz face-first specialist.
This is the route for a mixed workload. A clinic that regularly crosses face, body and moderately deeper superficial anatomy gains more from working range than from the largest MHz label. The demo tests the 50 mm footprint on curved facial regions and images the deepest real target. The L15 HD3 sells through the official Clarius store with the same scanner inclusions and Essentials options as the L20 HD3. The handheld ultrasound for dermatology page covers the broader specialty context.
Buyer framework · three frequency lanes
The 15/20/24 MHz Frequency Window
Choose by the deepest target the clinic must see reliably. Each lane names the frequency, the working depth and the models that fit it.
Image quality also rests on bandwidth, array, focusing, beamforming, Doppler sensitivity, settings, contact and operator technique.
What MHz Tells You, and What to Check Next
Search labels overlap. A buyer looking for high frequency skin ultrasound or high resolution ultrasound for skin is comparing superficial ultrasound machines, and a HIFU platform is a separate treatment purchase. In a clinic that already runs one, the same scanner measures skin-to-SMAS depth before each HIFU cartridge is picked, and the HIFU depth chart lists the published depths site by site. For aesthetic ultrasound equipment, the purchase begins with target depth and ends with a same-target Doppler and record-workflow test.
Higher frequency trades penetration for superficial detail
Higher frequency creates a shorter wavelength and finer superficial detail, while attenuation rises and penetration falls. Cross-brand image quality also rests on the array, beamforming and settings behind the top-frequency label.
Using 1,540 m/s as the soft-tissue sound speed, the wavelength is about 0.103 mm at 15 MHz, 0.077 mm at 20 MHz and 0.064 mm at 24 MHz. Axial resolution also depends on spatial pulse length, bandwidth, focusing and system processing.
Read a range and two settings as different specifications
Clarius gives a band such as 8–20 MHz; Suresult gives two settings such as 18 and 24 MHz. The demo-day test compares both probes on the same target.
What to check beyond MHz
- measured system resolution;
- slow-flow Doppler sensitivity;
- near-field behavior;
- frame rate under sustained use;
- probe contact on facial curves;
- app or connection stability;
- whether export requires a paid plan;
- operator repeatability.
Fifteen MHz is the consensus floor
A 2025 modified Delphi consensus involving 15 experts across seven specialties and 11 countries recommended a minimum linear 15 MHz transducer for learning and routine diagnostic work in cosmetic filler practice. The same consensus treated B-mode, Color Doppler, spectral Doppler and picture/video archiving as mandatory, with Power Doppler recommended. Handheld devices were acceptable.
That is a strong purchasing floor for filler practice. Above it, the choice turns on slow-flow Doppler, footprint, archive and usability. Facial arteries run slowly; the Doppler settings for filler vascular occlusion set the Color scale near 3 cm/s and lower the PRF and wall filter.
Read vendor depth as a device field
A vendor depth is a selectable display setting; a paper’s depth is tissue penetration measured under its own setup. Use vendor depth as a device field, then test the real anatomy at the real depth. Specialized clinical and research systems reach 30–70 MHz as a separate class, with their own form factor, field of view, penetration and purchasing context.
The practical conclusion: frequency narrows the shortlist. The same-target image, Doppler response, footprint, record loop and sustained workflow select the system.
High-Frequency Ultrasound Machine Price: Five-Year Totals
High frequency ultrasound machine price is the first line of the purchase; required software sets the rest of the five-year total. The table puts each scanner beside its annual and one-time software routes.
Suresult totals update live from the Suresult store; Clarius prices and plans were read on the Clarius US store on October 30, 2026. The Clarius annual route adds five payments of $695 to the scanner price, and the one-time route adds $2,500. Suresult’s checkout price covers shipping, customs clearance, duties and taxes: No Hidden Fees. The imaging software is free for the life of the probe, so each Suresult five-year total equals its hardware price.
| Purchase route | Hardware price | Recurring fee used | Five-year total, annual plan | Five-year total, one-time |
|---|---|---|---|---|
| Suresult L24Pro | $4,185 | Included | $4,185 | $4,185 |
| Suresult L20 | $3,000 | Included | $3,000 | $3,000 |
| Clarius L20 HD3 | $5,395 | $695/year Essentials | $8,870 = $5,395 + (5 × $695) | $7,895 = $5,395 + $2,500 |
| Clarius L15 HD3 | $3,795 | $695/year Essentials | $7,270 = $3,795 + (5 × $695) | $6,295 = $3,795 + $2,500 |
Each total is hardware plus the software the clinic needs for five years. Clarius Essentials adds dedicated aesthetics presets, T-Mode AI Aesthetics, Vessel Depth AI, Needle Enhance, PW Doppler, cloud storage and DICOM, so a clinic that uses them counts them in the value. For a quote matched to the clinic’s targets, send the target list.
Choose the Highest Frequency When…
A specialist pays off when the clinic has the specialist workload and all five conditions below hold.
Run This Demo-Day Acceptance Test
The acceptance test puts the intended operator on the exact system being purchased: scan, show flow, save, retrieve and sustain the workflow.
- Bring a target-depth list.Write down the shallowest and deepest structures the clinic must see, plus the curved facial regions where footprint and contact are difficult.
- Use the intended operator and display.Scan on the exact iPhone, iPad, Android or Windows hardware and current OS, with the clinic’s own operator performing every decisive step.
- Compare B-mode at the same real target.Use the same appropriate subject or phantom, anatomy, plane, depth and comparable gain strategy. Save raw stills and cine rather than photographing the screen.
- Test the required vascular modes.Run Color, Power and PW or spectral Doppler on a slow facial vessel; the live flow signal shows slow-flow sensitivity.
- Complete the record loop.Label, save, export, close and reopen the exam. Suresult probes save local files and DICOM with free software; on Clarius, local storage, cloud storage and DICOM come with Essentials (Clarius US store, October 30, 2026).
- Test sustained use.Run long enough to observe heat, frame rate, battery, grip, screen glare and connection recovery. Interrupt the connection once and check that the saved work is intact.
- Test the support path.Use the actual onboarding resource and ask how a failed connection, software issue or hardware service case is escalated. Match the answer to the written bundle.
Pass condition: the intended operator completes the real image, Doppler and record workflow at the deepest recurring target on the exact quoted configuration. Every critical step passes before the order.
How We Evaluated These Machines
We ranked four current purchase routes for a U.S. clinic prioritizing diagnostic superficial facial imaging. The five criteria were fixed before ordering the models: frequency-to-task fit, diagnostic workflow completeness, five-year ownership cost, support and adoption path, and routing to the right model for the rest of the work.
We used official U.S. product and store pages, read October 30, 2026, for price, software, frequency, depth and platforms, and primary or peer-reviewed sources for diagnostic-ultrasound definitions and physics.
The final selection rests on a live, same-target acceptance test and the exact written configuration.
High-Frequency Ultrasound Machine FAQ
What MHz ultrasound probe do I need to see dermal fillers and facial arteries?
Use 18–24 MHz for the superficial face and 16–20 MHz for the facial artery. Published depths run from 2.52 mm at the dorsal nasal artery to 5.6 mm at the superior labial artery, well within the 20 MHz reach of about 10 mm (Mlosek 2021), while the facial artery deepens from 6.27 mm near the jawline to 8.04 mm beside the nose. Pair the band with Color Doppler, which the 2025 WFUMB position paper requires in every aesthetic study. The Suresult L24Pro runs 18/24 MHz and the L20Pro 16/20 MHz, both with Color, Power and PW Doppler.
What is a high-frequency ultrasound machine used for?
A high-frequency ultrasound machine is used to create real-time B-mode and Doppler images of superficial anatomy such as skin, subcutaneous tissue, vessels, and other shallow targets. In aesthetic practice, clinics use it for diagnostic imaging and documentation; HIFU is the separate device that delivers treatment energy. The correct frequency route is the highest usable setting that still reaches the clinic’s deepest recurring target.
Is diagnostic high-frequency ultrasound the same as HIFU?
No. Diagnostic high-frequency ultrasound sends sound waves and receives returning echoes to create real-time B-mode and Doppler images. HIFU is a treatment technology that concentrates acoustic energy at a focal zone to heat or ablate tissue. They are different device categories with different functions, workflows, and purchase criteria.
Is a 15 MHz linear probe enough for aesthetic filler injections, or do I need 20–24 MHz?
15 MHz is the floor: the 2025 modified Delphi consensus recommends a minimum linear 15 MHz transducer for learning and regular diagnostics, and the 2025 WFUMB position paper sets the same minimum. For superficial filler work, go higher. The forehead, glabella, nose and lip arteries sit 2.52 to 5.6 mm deep, inside the reach of an 18–24 MHz band, and Jaguś 2021 states that 18–22 MHz shows vessels about 0.1 mm across. The Suresult L24Pro runs 18/24 MHz for that work; the L20Pro’s 16/20 MHz suits the cheek, jawline and the facial artery, which deepens to 8.04 mm, with depth settings to 40 mm.
What ultrasound frequency is best for imaging facial skin layers, the SMAS and facial vessels before injections?
Set the band by depth. Dermis and subcutis: 20–24 MHz, inside the 20–30 MHz range Mlosek 2021 favors once a scan includes those layers. The forehead, glabella, nose and lip arteries, 2.52 to 5.6 mm deep: 18–24 MHz. The facial artery, 6.27 to 8.04 mm deep: 16–20 MHz. Vasconcelos-Berg 2024 images the SMAS over the zygoma at 18 and 20 MHz; FaceAtlas AI, included for 3 months with the Suresult L24Pro and L20Pro, labels skin, fat and SMAS on the live image.
What is the difference between 20 MHz and 24 MHz ultrasound?
At 24 MHz the wavelength in soft tissue is about 0.064 mm, against 0.077 mm at 20 MHz, so 24 MHz brings finer superficial detail and 20 MHz reaches deeper tissue. The Suresult L24Pro and L24 run 18/24 MHz with depth to 25 mm; the L20Pro and L20 run 16/20 MHz with depth to 40 mm. Bandwidth, array design, beamforming, settings, Doppler sensitivity, contact and operator technique also shape the usable image.
What is the best high-frequency handheld ultrasound probe for facial filler work in 2026?
Our first pick for face-first filler work is the Suresult L24Pro: 18/24 MHz, depth from 10 to 25 mm, B and M modes plus Color, Power and PW Doppler, and 3 months of FaceAtlas AI included. The Suresult L20 is our value pick at $3,000, with 16/20 MHz and depth to 40 mm for the cheek, jawline and the facial artery; the L20Pro adds 64 more elements (256 vs 192) and 3 months of FaceAtlas AI on the same band. The L20 vs L24 comparison settles which band fits a clinic’s caseload.
How much does a high-frequency ultrasound machine cost in 2026?
Suresult prices update live from the Suresult store: $3,000 for the L20 and $4,185 for the L24Pro, with lifetime free software. On October 30, 2026 the Clarius US store priced the L20 HD3 at $5,395 and the L15 HD3 at $3,795, with Essentials at $695 for one year, $1,785 for three years or $2,500 as a one-time license.
What should a buyer test before choosing a scanner?
Test the intended operator, display device, and deepest recurring target. Compare B-mode and the required Color, Power, or PW Doppler workflow; then label, save, export, close, and reopen an exam. Also check footprint and contact, connection recovery, sustained heat and battery behavior, device compatibility, cleaning, support escalation, and the exact quoted software and warranty bundle.
What does a subscription-free scanner cost over five years?
Its hardware price. The Suresult L20 at $3,000 and the L24Pro at $4,185 run their imaging software free for the life of the probe, so each five-year total equals the hardware price. Five annual Clarius Essentials payments of $695 make the total $8,870 for the L20 HD3 and $7,270 for the L15 HD3 (Clarius US store, October 30, 2026).
Sources & Verification Dates
- U.S. Food and Drug Administration. Ultrasound Imaging. Diagnostic echo imaging and Doppler overview. Accessed July 30, 2026.
- U.S. Food and Drug Administration. Sonalleve MR-HIFU Instructions for Use. Focused therapeutic-energy description. Accessed July 30, 2026.
- Velthuis PJ, Alfageme F, Cartier H, et al. The use of ultrasound imaging in aesthetic injectables: A modified Delphi consensus. J Plast Reconstr Aesthet Surg. 2025;104:33–37. PMID 40101353. Accessed July 30, 2026.
- Wortsman X, et al. Guidelines for Performing Dermatologic Ultrasound Examinations by the DERMUS Group. Accessed July 30, 2026.
- NCBI Bookshelf. Medical Imaging Systems, Chapter 11. Frequency, wavelength, resolution and attenuation. Accessed July 30, 2026.
- Mlosek RK, Migda B, Migda M. High-frequency ultrasound in the 21st century. J Ultrason. 2021;20(83):e233–e241. PMID 33500789. Accessed July 30, 2026.
- Suresult. L24Pro official product page. Price, frequency, depth, architecture, modes, platforms, software terms and FaceAtlas AI terms read October 30, 2026.
- Suresult. L20 official product page. Price, frequency, depth, modes, platforms and software terms read October 30, 2026.
- Suresult. L14Pro official product page. Frequency and depth read October 30, 2026.
- Clarius (store.clarius.com). L20 HD3 official U.S. store page. Scanner price, Essentials options, frequency, depth, workflow, inclusions and platforms read October 30, 2026.
- Clarius (store.clarius.com). L15 HD3 official U.S. store page. Scanner price, Essentials options, frequency, depth, workflow, inclusions and platforms read October 30, 2026.
- Cotofana S, Alfertshofer M, Frank K, et al. Relationship Between Vertical Glabellar Lines and the Supratrochlear and Supraorbital Arteries. Aesthet Surg J. 2020;40(12):1341–1348. PMID 32469392. Accessed October 30, 2026.
- Cotofana S, Alfertshofer M, Schenck TL, et al. Anatomy of the Superior and Inferior Labial Arteries Revised: An Ultrasound Investigation and Implication for Lip Volumization. Aesthet Surg J. 2020;40(12):1327–1335. PMID 32469050. Accessed October 30, 2026.
- Franceschelli A, Cazzulani M, Urso SU, et al. In Vivo Ultrasound Study of the Angular Artery Anatomy: Practical Indications for the Treatment of the Deep Pyriform Space. Aesthet Surg J Open Forum. 2024;6:ojae113. PMID 40007597. Accessed October 30, 2026.
- Ortiz Middleton E, Aguilar A. Anatomical Mapping of Nasal Arteries in Chilean Patients Using Doppler Ultrasound: Clinical Application for Injectables. Aesthet Surg J Open Forum. 2025;7:ojaf016. PMID 40255966. Accessed October 30, 2026.
- Pourani MR, Ebrahimzade M, Goudarzi E, et al. Evaluation of Facial Artery Course Variations, Diameters, and Depth Using Doppler Ultrasonography: A Systematic Review and Meta-Analysis. J Cosmet Dermatol. 2025;24(9):e70431. PMID 40874402. Accessed October 30, 2026.
- Phumyoo T, Jiirasutat N, Jitaree B, et al. Localization and Topography of the Arteries on the Middle Forehead Region for Eluding Complications Following Forehead Augmentation: Conventional Cadaveric Dissection and Ultrasonography Investigation. J Craniofac Surg. 2020;31(7):2029–2035. PMID 32604295. Accessed October 30, 2026.
- Vasconcelos-Berg R, Desyatnikova S, Bonavia P, et al. Best Practices for the Use of High-Frequency Ultrasound to Guide Aesthetic Filler Injections, Part 2: Middle Third of the Face, Nose, and Tear Troughs. Diagnostics (Basel). 2024;14(22):2544. PMID 39594210. Accessed October 30, 2026.
- Jaguś D, Skrzypek E, Migda B, et al. Usefulness of Doppler sonography in aesthetic medicine. J Ultrason. 2021;20(83):e268–e272. PMID 33505714. Accessed October 30, 2026.
- Chammas MC, Sigrist R, Alfageme F, et al. WFUMB Position Paper: Consensus on Best Practice in Aesthetic Dermatologic Ultrasound. Ultrasound Med Biol. 2025;51(11):2173–2193. PMID 40866164. Accessed October 30, 2026.
- Suresult. L20Pro official product page. Frequency, depth, elements, scan time, imaging modes, platforms and FaceAtlas AI terms read October 30, 2026.
- Suresult. L24 official product page. Frequency and depth read October 30, 2026.
Get the Frequency Route Matched to Your Real Work
Share the target anatomy, deepest recurring target, monthly volume, display devices, archive requirements, software-fee tolerance and budget. The reply routes the clinic to the L24Pro, L20Pro, L20 or L14Pro, or to the competing system that fits, and names the deciding condition.