Suresult D3Ultra software window during a rib scan: a continuous bright cortical line running the length of the rib in long axis with clean acoustic shadow beneath, 40 mm depth and H10.0 MHz on the linear head

A lower-rib survey run end to end on a linear probe — short axis to find the rib, long axis to follow its cortex, and the costochondral junction where the picture changes — with every moment timestamped, the settings read off the device screen, and the whole recording transcribed.

페르난도 마리즈, 의학박사페르난도 마리즈, 의학박사Gynecology, pelvic surgery, sonography
마리즈 박사 소개

I am Dr. Fernando Mariz, a gynecology and pelvic surgery physician practicing in New York City. Before my medical career, I served in the U.S. Marine Corps, where I developed the discipline, focus, and steadiness that continue to shape the way I care for patients today. At Maiden Lane Medical, my work covers women’s health, preventive care, sonography, pelvic pain, abnormal uterine bleeding, and minimally invasive gynecologic procedures.

제일린 아빌라, 의학박사제일린 아빌라, 의학박사Emergency medicine, POCUS education
아빌라 박사에 대하여

I am Dr. Jailyn Avila, an emergency medicine physician, educator, and digital health innovator based in Southern California. My clinical work is rooted in emergency care, while my teaching focuses on point-of-care ultrasound, residency education, and practical training for physicians. Through my roles with Emergent Medical Associates, UHS SoCal MEC Emergency Medicine Residency, Core Ultrasound, and FemInEM, I work at the intersection of patient care, medical education, and accessible digital learning.

Verified authorsUpdated September 5, 2026

Recorded on a D3Ultra and posted to the Suresult channel, 12 October 2025. The poster above and the frozen frame further down are two different moments of the same live scan; the walkthrough runs 6:42, and the transcript covers it to 6:09.

Quick answer

A rib fracture shows on ultrasound as a break in the bright line of the rib cortex, and often as a fine raised stripe of lifted periosteum with a hematoma beneath it. You find both with a high-frequency linear probe placed at the point of maximum tenderness: across the rib to locate it, then along the rib to follow the cortex. It is a better first test than a chest film, and the recording puts the numbers on screen at 0:56 — ultrasonography found 58 of 59 rib fractures where the oblique rib view found 27 and the PA chest radiograph 24, in less than half the examination time. European guidance says the same thing in guideline form: when radiography is negative and clinical suspicion of an acute fracture is high, scan. What this walkthrough demonstrates is the normal, and that is precisely its value — the presenting clinician follows an intact cortex along a lower rib all the way to the costochondral junction. I would start anyone new to this exam exactly there, because you cannot recognise a step-off until you know precisely what an unbroken rail looks like at 10 MHz. Start at 4:31 for the scanning, at 0:46 for the evidence.

Looking for a device rather than the exam? The emergency medicine hub covers the models used for trauma and chest work, and the D3Ultra product page carries the full specification and current price.

Two signs

What ends the search, and what fools it

The rib cortex is a bright rail with clean shadow underneath. Two findings break that pattern for real; four normal structures break it for no reason at all. Click either sign to jump the video to the moment it is taught.

Fractures detected, of 59 confirmed in 61 patients with minor blunt chest trauma

Ultrasonography98.3%58 of 59 fracturesOblique rib view45.8%27 of 59PA chest radiography40.7%24 of 59

The study the recording displays at 0:56: Pishbin et al., Chinese Journal of Traumatology 2017. Mean examination time was 12 minutes for ultrasonography against 27 for radiography. Full citation under Sources.

Costochondral junctionA slight angulation or a narrow gap without callus is a normal variant here.Tendon and ligament insertionsAttachment zones are physiological cortical discontinuities.Nutrient vessel channelsVessels penetrating the cortex read as a break in it.Unfused ossification centresIn children, accessory centres and growth plates look like fragments.
0:00The argument, the evidence and the cautions4:31The rib scanned on camera6:09Close

the argument, the evidence and the cautionsthe rib scanned on cameraclose

No fracture is scanned on camera in this recording. The rib followed from 4:56 is intact, and the labelled picture of a fractured rib that appears at 5:41 is a reference image rather than a live acquisition — which is worth knowing before you watch, and does not cost the walkthrough anything, because the skill it teaches is recognising the normal rail. The presenting clinician also names osteophytes, erosions and pseudo-erosions among the look-alikes at 1:49; those stay in the transcript as his own words. The four listed above are the ones carried by the sources at the foot of this page.

Timestamped

Key moments, with the settings

The third column is the part normally missing from a scan video: the depth, transmit frequency and gain showing on the device at that moment. What is striking on this recording is that they never change. One depth, one frequency, one gain carry the entire survey — and that frequency is the ceiling of what this probe’s linear array offers.

Time What is on screen Transducer, depth, frequency, gain
0:00 Why a rib fracture is an ultrasound problemteachingPresenting clinician to camera
0:46 The comparison study and the EFSUMB bone recommendation, on screenteachingThe cited paper, then the recommendation list
1:29 Where ultrasound falls short: a narrow slice, and bone you cannot reachteachingPresenting clinician to camera
2:08 The look-alikes, and why you scan the other sideteachingPresenting clinician to camera
2:36 Three reasons you are scanning: unknown site, localised pain, or following healingteachingLive scan of the lower ribs begins under the narration Linear · D 40 mm · F H10.0 MHz · GN 105 dB
3:02 Scan plane: longitudinal along the rib, perpendicular to the fracture lineteachingProbe tracking along the lower ribs Linear · D 40 mm · F H10.0 MHz · DR 80
3:57 Cartilage against cortex, and positioning a patient who cannot moveteachingProbe tracking along the lower ribs Linear · D 40 mm · F H10.0 MHz · DR 80
4:31 Short axis first: the rib, its shadow, and the pleura betweenShort-axis view of the rib on the device screen Linear · D 40 mm · F H10.0 MHz · ENH 0 · Compound OFF
4:56 Rotate to long axis and track the cortex to the costochondral junctionA continuous bright cortical line followed along the rib Linear · D 40 mm · F H10.0 MHz · GN 105 dB · MI 0.9
5:37 Above the cortex: hematoma and fluid lifting the periosteumLive scan, then a labelled reference image of a fractured rib Linear · D 40 mm then 60 mm · F H10.0 MHz · DR 80

Settings transcribed from the device interface visible in the recording. Depth is the D value on screen; frequency is the F value, harmonic. The first four rows are argued against slides and reference images, so no device panel is on screen for them. Depth steps from 40 mm to 60 mm inside the final row.

Reading the images

What this scan shows

The rib cortex is the whole exam. Bone reflects almost all the sound that reaches it, so at 10 MHz the surface of the rib draws as a bright continuous line about a centimetre down, with nothing but acoustic shadow beneath. You are not imaging the inside of the bone and never will be. You are reading its surface, and a fracture is a break in that surface.

Long-axis rib scan on a Suresult D3Ultra: the bright cortical line runs across the field with layered soft tissue above it as the probe approaches the costochondral junction, 40 mm depth, H10.0 MHz
The cortex in long axis, frozen at 5:30. The rail the presenting clinician is following: a bright, continuous cortical line with layered soft tissue above it and clean shadow below. This is the normal that a step-off has to be measured against. Linear array · D 40 mm · F H10.0 MHz · GN 105 dB · DR 80 · Compound OFF.

Find the rib in short axis first. Across the rib you get a rounded bright cap with a dark shadow falling away beneath it, and between two of those caps sits the pleural line, deeper and sliding with the breath. That is the orientation check, and it is worth repeating every so often: a bright line that is not casting a shadow is pleura, not cortex. Then rotate ninety degrees. In long axis the cortex becomes a rail you can follow, and following it is the exam — along one rib, down an intercostal space, along the next.

Two findings end the search. The first is a step or an interruption in that bright rail. The second sits above it: blood under the periosteum lifts a fine bright stripe off the bone with a dark collection between the two, and it is the sign that survives when the cortex itself looks passable. Expect the picture to change at the costochondral junction, where cartilage stops reflecting the way bone does and the sound passes into the rib instead. That transition is normal, and taking it for a break is the commonest way I see this exam go wrong.

Verbatim

Full transcript

Transcript — 6:42, 36 passages

Transcribed from the recording and edited for readability; square brackets mark an editorial clarification, and every timestamp jumps the video.

Why ultrasound, and not only radiography

0:00Today we’re going to use a Suresult D3Ultra to look for rib fractures.

0:07Now, a lot of people, a lot of doctors, when they think of a fracture, they think radiographs, they think X-rays. And even myself, I was trained that way. But in fact, ultrasound is actually much better.

0:21But wait — ultrasound, that’s soft tissue. But the cortex glows brightly, so you can see a discontinuity in the cortex. And soft tissue: you can see a hematoma underneath the periosteum. The periosteum gets lifted by, basically, fluid from the injury.

0:38So it is very, very sensitive. It’s very easy to pick up a fracture with ultrasound compared to a radiograph.

The evidence put on screen

0:46In fact, in one study specific to rib fractures — it was back in 2017 — they found that ultrasound had a sensitivity, caught 98 % of the fractures, whereas the oblique rib view and the PA chest radiographs detected 46 % and 41 % of rib fractures respectively.

1:07So that’s very, very impressive.

1:09And in fact, there’s a consensus statement that says, if you have a patient and they’ve had radiographs, but you’re like, “I still have a clinical suspicion that they have a fracture” — they say, well, get an ultrasound and satisfy your clinical suspicion. Because in general, ultrasound has a much higher sensitivity.

Where ultrasound falls short

1:28Now, the downsides of ultrasound: you have to screen through — you’re taking a very narrow slice. So you have to really screen through the bones and look all around the bones.

1:39And there’s some places you just can’t get the unit, so you can’t screen the whole body, every bone, completely — because you just can’t manipulate the ultrasound unit around every bone.

1:49The other caution is you have to make sure you’re not mistaking something like an osteophyte, or an erosion, or what’s called a pseudo-erosion, for a fracture.

1:59There’s often a little depression where a ligament attaches, and you don’t want to mistake that as a discontinuity of the cortex.

2:07And of course, children look really strange no matter what type of imaging you’re using. So you don’t want to mistake normal anatomy in a child for a fracture.

2:16And remember, you have both sides of the person, so scan both sides if you want to see a normal — and use your split screen.

2:23[This is] specific to rib fractures. If you wanted to, for example, check the lungs for pneumothorax or hemothorax, you have the right tool in your hands already. Just take 60 seconds and you can check for those as well.

Why you are scanning at all

2:36Okay. So you may have no idea where the injury is. You may have to screen through every single rib. Or you may have a clinical indication of sort of where the injury might be.

2:47And you may know exactly where the injury is, because you’re just following the injury and you’re monitoring healing.

2:52In fact, it is recommended to follow fractures with ultrasound imaging, because you can see the callus and you can basically watch it heal, if you deem that useful.

Scan plane and technique

3:02Now, for the fracture, we want an image sort of perpendicular to the fracture line. Now of course, we don’t know where the fracture is — if there is a fracture — but ideally we’ll see that discontinuity as it sort of jumps across that line.

3:14So for ribs, we know where the fracture is going to be. The fracture is going to be sort of up and down. So we’re going to go longitudinal along the rib.

3:22Now, how I’m going to do that is: I can palpate, and I can sort of feel and follow one rib — or basically follow the intercostal space, because that’s easier to follow. And then I can just basically have the transducer sort of follow just on top.

3:33And I can just follow along the rib, go down one intercostal space, follow along the rib.

3:38If you get lost, you can of course figure out where you are by taking a coronal view, or a view sort of transverse to the rib. And you can look at the ribs — because you don’t want to be looking at the pleura of the lungs and think you’re looking at the ribs.

3:50So this is a good idea: every once in a while, turn it 90 degrees and make sure you’re taking a picture of what you want.

Cartilage, and a patient who cannot move

3:57When you switch to cartilage, cartilage doesn’t look like normal bone and cortex. You can’t see through cortex, and you can see through cartilage. So it’s a striking change when you start to hit cartilage.

4:08In terms of patient positioning: if someone has a rib fracture, breathing probably isn’t very easy for them, moving around probably isn’t very easy for them. So take an image in whatever position they’re in — if they’re lying on their side, if they’re sitting, if they’re standing.

4:24Nice thing about ultrasound is you can sort of work around whatever body position they’re in, if you have a handheld ultrasound.

The rib, scanned on camera

4:31And let’s just get into it. I’ll turn it on here.

4:35And I’ll find the rib. And let’s take a short axis view.

4:44We can see where that rib is, right? It stands up in between the ribs. We have the pleura. So you don’t want to be in the pleura — you want to be the ribs, which are more superficial. But I can rotate this.

4:56So what I’m looking for is this cortex, and I want to make sure that it’s continuous. And I can follow it, and follow it, and follow it, and follow it — there it is again — and follow it, and follow it, and follow it.

5:18And then at a certain point, you’re going to hit the costochondral junction. Just double-check where you are, what’s going on.

5:25And you can see I go from not being able to see through the cortex, and then all of a sudden now I can see through the rib, right? So now I’m at cartilage instead of bone.

5:37Now remember, it isn’t just the fact that the cortex is continuous. You can also look above the cortex, right? And you’ll have basically a hematoma and fluid basically lifting up the periosteum, if there is a fracture. So keep an eye out for that as well.

Close

5:55Now if you want, you can go into a quick lung exam, but I have another video for that — or you can go to my website, [where] I think I have an hour-long video of trauma ultrasound that will explain how to do a trauma lung exam.

6:08But that’s it for the ribs.

6:09[Sponsor segment omitted, 6:09–6:42]

Hardware

Device and settings

One probe, one setting, the whole survey. The left column is the published specification; the right column is what the device interface actually showed while this exam was being run, and the right column is the one I would work from if you are reproducing it. Chest-wall work wants the linear array at the top of its frequency range, because the cortex sits a centimetre down and resolution beats penetration there. If the same probe is going to look for an effusion at the base afterwards, that is a convex-array job and these are the wrong numbers to copy.

Published specification

결과 D3Ultra

Convex · linear · phased in one head — $2,976

  • 컨벡스3.2 / 5.0 MHz · 90–300 mm · 45°
  • 리니어7.5 / 10 MHz · 20 / 40 / 60 / 100 mm · 40 mm
  • 단계적3.2 / 5.0 MHz · 90–300 mm · 60°
  • 모드B, M, Color Doppler, Power Doppler, PW Doppler
  • Array192 elements · 64 channels · 256 grey levels
  • Gain / DR30–105 dB · 40–110
  • Body156 × 65 × 20 mm · 263 g · 2 h scanning
  • 플랫폼iOS, Android, Windows · dual-band Wi-Fi

Read off the screen in this recording

  • ArrayLinear · unchanged for the whole survey
  • 깊이D 40 mm · the shallowest step but one, and it steps to 60 mm at 5:58
  • 빈도F H10.0 MHz, harmonic · the top of the linear range
  • 이득GN 105 dB · the top of the published range
  • Dynamic rangeDR 80
  • ProcessingENH 0 · Compound OFF
  • OutputMI 0.9 · TIS 0.2
  • ModeB throughout · no M-mode or Doppler is used on this exam

Asked on this search

Rib fracture questions

Can you see a rib fracture on ultrasound?

Yes. The rib cortex reflects almost all the sound that reaches it, so it draws as a bright continuous line with acoustic shadow beneath; a fracture appears as a sharp discontinuity or step-off in that line. A second sign sits above the bone: bleeding lifts the periosteum away from the cortex, leaving a fine raised bright stripe with a hypoechoic collection under it. Both are found with a high-frequency linear probe placed at the point of maximum tenderness, first across the rib to locate it and then along the rib to follow the cortex. The second sign is the one I would not skip: it stays visible when the cortex itself still looks intact.

Source: ACEP Sonoguide — Musculoskeletal Ultrasound. Accessed September 5, 2026.

Is ultrasound more sensitive than an X-ray for rib fractures?

In a cross-sectional study of 61 patients with minor blunt chest trauma, ultrasonography detected 58 of the 59 rib fractures found (98.3 %), while the oblique rib view detected 27 (45.8 %) and PA chest radiography 24 (40.7 %). The ultrasound examinations also took less time, averaging 12 minutes against 27 for radiography. European guidance reflects this: EFSUMB recommends ultrasound in accessible bone areas when radiography is negative but clinical suspicion of an acute fracture is high.

Source: Pishbin E, Ahmadi K, Foogardi M, Salehi M, Seilanian Toosi F, Rahimi-Movaghar V. Comparison of ultrasonography and radiography in diagnosis of rib fractures. Chinese Journal of Traumatology 2017;20(4):226–228. Accessed September 5, 2026.

What can be mistaken for a fractured rib on ultrasound?

Several normal structures produce a discontinuity in the cortical line. At the costochondral junction a slight angulation or a narrow gap without callus is a normal variant. Tendon and ligament attachment zones, and nutrient vessels penetrating the cortex, are physiological breaks in the bone surface. In children, growth plates and accessory ossification centres read as fragments. Correlating the finding with the point of tenderness and comparing the same rib on the other side resolves most of them.

Source: Abu-Zidan FM, Alao DO, Cevik AA. Point-of-care ultrasound (POCUS) diagnosis of rib fractures. World Journal of Emergency Surgery 2025;21(1):1. Accessed September 5, 2026.

How do you scan a rib for a fracture?

Place a linear probe perpendicular to the rib for a transverse view at the site of highest tenderness, then rotate 90 degrees and trace along the length of the rib, watching the cortical line for a break and the tissue above it for a hematoma. Following the intercostal space is easier than following the rib itself, and that is the habit I would build first. Turning back to the transverse view periodically confirms you are still on rib rather than on pleura, and the patient can stay in whatever position they can tolerate.

Source: Duong HA. Cracking the Case: Rib Fractures. ACEP Sports Medicine Section, 18 July 2025. Accessed September 5, 2026.

Provenance

출처

Which probe does your chest-wall work actually need?

A rib survey asks for the highest frequency you own and almost no depth. The lung and effusion work that usually follows it asks for the opposite. A three-in-one head covers both from one device; a dedicated pair covers both better, for more money. Tell us the setting and the case mix and you will get a direct recommendation in one conversation — one probe, two, or neither.


작성자 아바타

About Dr. Fernando Mariz, MD

저는 뉴욕시에서 산부인과 및 골반외과 전문의로 활동하고 있는 페르난도 마리즈 박사입니다. 의사의 길을 걷기 전, 저는 미 해병대에서 복무했으며, 그곳에서 오늘날까지도 환자 치료 방식에 지대한 영향을 미치고 있는 규율, 집중력, 그리고 침착함을 기를 수 있었습니다. 메이든 레인 메디컬(Maiden Lane Medical)에서 저는 여성 건강, 예방 진료, 초음파 검사, 골반 통증, 자궁 출혈 이상, 그리고 최소 침습적 부인과 시술 등을 담당하고 있습니다.

답글 남기기

이메일 주소는 공개되지 않습니다. 필수 필드는 *로 표시됩니다